Development of a full-scale apparatus to assess thermal protective performance of garments under highly intensive heat flux exposures

Author:

Kang Sungwook1,Kwon Minjae12,Choi Joung Yoon1,Choi Sengkwan3ORCID

Affiliation:

1. Fire Testing & Research Centre, Division of Fire Safety, Korea Conformity Laboratories, Republic of Korea

2. Advanced Functional Nanohybrid Material Laboratory, Department of Chemistry, Dongkuk University, Republic of Korea

3. School of the Built Environment, Ulster University, Jordanstown Campus, UK

Abstract

This study discusses the development process of a full-scale test facility composed of a high-performance radiant heating system, a life-sized instrumented thermal manikin system with sensing assemblies, associated equipment and in-house software controlling the entire system. This test system was aimed to be used to examine the behaviour of emergency-responder garments and subsequently to find weaknesses of turnout gears at critical thermal conditions greater than a standard 84-kW/m2-intensity, thereby contributing to improving the survival chance of firefighters who could be requested to execute an emergency evacuation from an unexpected growth of modern fires. To impose a target 126-kW/m2-irradiance throughout the garment-dressed manikin’s exposed surface for a limited period of time (12 s) as uniformly, consistently, stably and safely as possible, several technical aspects were considered: the amounts of heat-source power and electric power-supply; areas of heating and receiving and their geometrical relationship; a practical percentage of the maximum heater-capability; efficiencies of electric power-supply and water-cooling; movable equipment; and safety equipment. Two analytical models were encoded using a finite difference method in the LabVIEW platform to determine a burn injury distribution throughout the manikin-shell in association with the measurement data from the test system. The heating system and software were validated in respect of the heating consistency, vertical intensity variation, intensity-rise rate and discrepancies between the existing and present models. It was proved that the heating system is capable of increasing its heat emission up to 126 kW/m2 within 1.5 s, maintaining the intensity-level with less than 9-kW/m2-change for 12 s, and distributing the intensity-level with less than 11-kW/m2-variation along the vertical direction, from 45-cm- to 155-cm-height. The development process can contribute to the ability to develop a large-scale test facility to test specimens under a critical thermal exposure condition for research purposes.

Funder

Korean Ministry of Public Safety and Security

Publisher

SAGE Publications

Subject

Applied Mathematics,Control and Optimization,Instrumentation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献