Hygrothermal performance of six insulation systems for internal retrofitting solid masonry walls

Author:

Jensen Nickolaj Feldt12ORCID,Bjarløv Søren Peter1,Rode Carsten1ORCID,Andersen Birgitte3,Møller Eva B1

Affiliation:

1. Department of Civil Engineering, Technical University of Denmark, Kgs. Lyngby, Denmark

2. BUILD – Department of the Built Environment, Aalborg University, Copenhagen SV, Denmark

3. Department of Bioengineering, Technical University of Denmark, Kgs. Lyngby, Denmark

Abstract

The study investigated the hygrothermal performance and risk of fungal growth in a phenolic foam system with a closed cell structure and a diffusion-open and capillary active lime-cork based insulating plaster, for internal retrofitting purposes. The setup comprised two 40-feet (12.2 m) insulated reefer container with controlled indoor climate, reconfigured with 24 holes (1 × 2 m each) containing solid masonry walls with embedded wooden elements on the interior side. Focus was on the conditions in the masonry/insulation interface and embedded wooden elements, and the performance of the two systems were compared to three diffusion-open insulation systems and one diffusion-tight. The effect of exterior hydrophobisation was also investigated. Relative humidity and temperature were measured in several locations in the test walls over 2½ years, and the risk of fungal growth was evaluated by on-site measurements and the VTT mould-growth model. The findings indicate that internally insulated walls with bare brick exterior surfaces performed poorly with high risk of fungal growth. The effect of exterior hydrophobisation was found to vary with the orientation and the installed insulation system, with a generally positive effect on walls facing south-west but limited effect for north-east. Furthermore, the more diffusion-tight insulation systems were found to perform better in combination with exterior hydrophobisation than the highly diffusion-open systems. The lime-cork insulating plaster showed high relative humidity and risk of moisture-induced problems. The on-site fungal tests showed no growth in the masonry/insulation interface inside the two insulation systems, probably due to high initial pH-value.

Publisher

SAGE Publications

Subject

General Materials Science,Building and Construction

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3