Thermal performance of lightweight steel framed wall: The importance of flanking thermal losses

Author:

Santos Paulo1,Martins Cláudio1,da Silva Luís Simões1,Bragança Luís2

Affiliation:

1. ISISE, Civil Engineering Department, University of Coimbra, Coimbra, Portugal

2. Civil Engineering Department, School of Engineering, University of Minho, Guimarães, Portugal

Abstract

The thermal performance of a modular lightweight steel framed wall was measured and calculated with three-dimensional finite element method model. The focus of this article is on the effect of flanking thermal losses. The calculated heat flux values varied from −22% (external surface) to +50% (internal surface) when flanking loss was set to 0 as a reference case, thermal transmittance equal to 0.30 W/(m2·K). Other critical parameters were the existence of fixing ‘L’-shaped steel elements and the perimeter thermal insulation (10 cm XPS).

Publisher

SAGE Publications

Subject

General Materials Science,Building and Construction