Optimization strategies of the envelope insulation for a detached house based on load sensitivity and thermal storage performance

Author:

Zhou Botao1,Zhao Juan1ORCID,Li Yongcai2,Gao Junmei1,Huang Bojing1,Wu Ritu1,Zhang Wenjie1,Tan Biao3

Affiliation:

1. School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an, China

2. School of Civil Engineering, Chongqing University, Chongqing, China

3. China Construction Science and Industry Corporation, Meishan, China

Abstract

Reasonable thermal insulation in cold regions is the key to improve the indoor thermal environment. In this paper, the detached house is taken as the research object, and the sensitivity analysis method is used to quantify the influence of each parameter on the building heat load in three different climate zones. The attenuation characteristics of the heat storage body to the outdoor temperature wave are studied by using the A·M Shklovel calculation method, and the thermal insulation strategy of the envelope structure is optimized by genetic algorithm (GA). The results show that the heat transfer coefficient of roof and exterior wall has the most significant influence on the building heat load. The mean effect response of each factor shows that the Delta (Delta is the value used in Taguchi design methodology to express the relative effect of each factor on the response) of roofs in the three regions is the highest, 3.061, 4.061, and 5.88, respectively. The influence of the type and thickness of the insulation material on the heat storage performance is different. The indoor and outdoor temperature wave penetration attenuation multiple increases with the increase of the thickness of the insulation layer, increases with the decrease of the thermal conductivity of the insulation material, and increases with the increase of the specific heat capacity. The choice of insulation materials is not only related to the above two parameters, but also directly affected by the price. Considering the influence of various factors, the economy of choosing expanded polystyrene board for thermal insulation in the three regions is the best. The optimal thermal insulation thickness of the north wall and roof is 8 and 16 cm (3A climate zone), 10 and 17 cm (2B climate zone), 13 and 20 cm (2A climate zone), respectively.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3