Microembolization Distal to a Basilar Artery Aneurysm Treated with Detachable Coils: A Case Study

Author:

Nicoletto Heather1,Douville Colleen1,Blaha Martin1,Newell David1

Affiliation:

1. Harborview Medical Center, Seattle, Washington.

Abstract

Introduction Since 1991, treatment of cerebral saccular aneurysms with coils by means of an endovascular approach has become increasingly used as an alternative to surgery. After this procedure, thromboembolic complications of stroke and transient ischemic attack, as well as silent embolic events seen on MRI, have been reported. The detection of microemboli (MES) in the cerebral circulation in a variety of conditions has been well established and has been observed in asymptomatic and symptomatic patients. We present a case of a 41-year-old man with subarachnoid hemorrhage (SAH) from a vertebrobasilar junction aneurysm treated with Guglielmi detachable coils. Multiple MES were detected in the basilar artery during serial transcranial Power M-mode Doppler (PMD) studies. A battery of tests was done to establish the source of embolization from the coiled aneurysm. Methods By use of conventional techniques, diagnostic TCD studies to determine the presence of vasospasm were performed using a Neuroguard Neuroflow (Medasonics, Freemont, CA). PMD, a new technique for the detection of emboli, was then performed using Spencer Technologies TCD100M (Seattle, WA). The TCD100M is a digital Doppler and displays Doppler power as intensity in an M-mode format. PMD signals are further colored red or blue according, to direction. MES are seen as high-power tracks in the PMD image as described by Moehring et al (Ultrasound Med Biol. 2002;28:49–57). Results Because of the possibility of multiple sources of embolization, our efforts were aimed at proving that the source of the embolization was the coiled aneurysm. Echocardiography, bubble studies, carotid duplex ultrasonography, and emboli monitoring of both middle cerebral and vertebral arteries did not show any MES. Power M-mode examination pointed to a depth of 85 mm in the basilar artery as the point where embolization began. This battery of tests strongly supports the presumptive origin and source of MES to be the coiled aneurysm of the vertebrobasilar junction. Conclusions Our case presentation demonstrates continuous silent microembolization from a previously coiled aneurysm. TCD has an important role in assessing patients with cerebral aneurysms for the detection of MES.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Transcranial Doppler Series Part V: Specialty Applications;American Journal of Electroneurodiagnostic Technology;2011-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3