Continuous Ultrasound Contrast Infusion as an Adjunct to Color Duplex Ultrasound in the Assessment of Aortic Endografts

Author:

Hodge Megan1,Parker Daniel1,Collado Esther1,Broadbent Karen2,Lumsden Alan B.2,McCollum Charles H.2,Noon George P.2,Bush Ruth L.2

Affiliation:

1. Methodist DeBakey Heart Center, Houston, Texas.

2. Baylor College of Medicine, Houston, Texas.

Abstract

Objective —We sought to evaluate continuous ultrasound contrast infusion Optison® as an adjunct to color duplex ultrasound (CDU) in endoleak detection. Methods —Endoleak surveillance, including CDU, Optison®, and computed tomography (CTA), was performed during 18 examinations. One (3 ml) vial of Optison® was diluted in a 57-ml syringe of normal saline (total 60 ml) and administered by infusion pump at 4 ml/hr. Transverse and sagittal views were performed of the aortic aneurysm sac, endograft, and arteries outside the aneurysm sac. Primary endpoints were endograft patency, the presence or absence of endoleak, and limb dysfunction. Results —There were no adverse events related to the contrast agent. Contrast appearance through the endograft occurred after an average of 1 min using a mean of 46.8 ml of contrast infusion per patient. There were 10 enodleaks clearly identified by CDU and Optison®, i.e., 2 type I, 4 type II, and 2 type III endoleaks with an additional study suspicious for endoleak. Using CDU and CTA, we found 9 studies without endoleaks whereas with Optison®, we found 8 studies normal. Comparatively, when using CTA, we identified only 2 definitive endoleaks. Of the 9 endoleaks identified by using CDU and Optison®, 2 of the endoleaks were type I and not observed on conventional CTA and were later confirmed by arteriogram. One study was deemed negative by CDU and Optison® whereas CTA results were suspicious. Body habitus was prohibitive for definitive CDU findings in one patient. Conclusions —Using continuous ultrasound contrast infusion as an adjunct to CDU allowed for longer imaging time and more extensive evaluation of the endograft, the aneurysm sac, and the perianeurysmal arteries in these patients. Our early results demonstrate that the use of ultrasound contrast for endoleak detection is reliable and may be considered a primary surveillance modality after endovascular aortic aneurysm repair.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Sonographic Evaluation of Aortic Endografts;Journal of Diagnostic Medical Sonography;2011-03

2. Spontaneous Regression of a Type I Endoleak Documented with Duplex Ultrasound;Journal for Vascular Ultrasound;2008-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP