Affiliation:
1. Civil Engineering, School of the Built Environment, Heriot-Watt University, Edinburgh, Scotland, UK
Abstract
A non-linear model of flashover, FLASHOVER A1, has been used to explore the dependence of the critical fire size necessary for the onset of flashover on the aspect ratio of the enclosure. It may be hypothesized that, overall, there is a dependence on aspect ratio. Further, it has been inferred that the critical upper layer temperature necessary for the onset of flashover is not fixed but depends upon the specific case assumed. It is not tenable to assume a single, fixed, temperature as a criterion for flashover, although this has often been done in the past.
Subject
Mechanical Engineering,Mechanics of Materials,Safety, Risk, Reliability and Quality
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献