Full-scale experimental study on fire suppression performance of a designed water mist system for rescue station of long railway tunnel

Author:

Meng Na1,Hu Longhua12,Liu Shuai1,Wu Long1,Chen Longfei1,Liu Binghai3

Affiliation:

1. State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui, China

2. Research Institute of University of Science and Technology of China in Shenzhen, Shenzhen, Guangdong, China

3. Hefei KDLIAN Safety Technology Co. LTD, Hefei, Anhui, China

Abstract

Rescue stations have been newly designed in some super-long mountain railway tunnels of China such as over 30 km long, as a new type of strategic counteract design for fire accident in tunnels. Water mist fire suppression systems are needed to be installed in such rescue stations to control the train fire. However, there is no design engineering experience for it. In this article, a full-scale experimental facility was built to study the fire suppression performance of water mist system in such railway tunnel rescue station. A series of full-scale tests was preliminarily conducted considering the fire position was on top of, inside, and under the train carriage with gasoline pool fire and wood crib fire used as fire sources. A design of water mist suppression system for such a fire scenario was presented, and its performance was tested. Experimental data on temperature, CO concentration, and radiation flux were collected and analyzed. The results showed that the water mist system could control fires, cool the air temperature in the rescue station, and strongly reduce the radiant heat flux in the vicinity of the fire source under various ventilation conditions. However, the visibility of the rescue station was much deteriorated after the injection of water mist, so that emergency lights and evacuation lights are necessary for personnel evacuation. The changes of fire extinguishing time with longitudinal ventilation velocities showed that longitudinal ventilation could provide both favorable and unfavorable conditions for water mist fire extinguishment. So, to achieve efficient fire suppression performance of water mist system, attention might be paid to the controls of tunnel ventilation system in the event of a fire in a railway tunnel rescue station. The design of the water mist system and the full-scale experimental data on the fire suppression performance presented in this article may serve as a reference for such engineering applications.

Publisher

SAGE Publications

Subject

Mechanical Engineering,Mechanics of Materials,Safety, Risk, Reliability and Quality

Reference43 articles.

1. Hu LH. Studies on thermal physics of smoke movement in tunnel fires. PhD Dissertation, University of Science and Technology of China, Hefei, Anhui, China, 2006.

2. Current safety issues in traffic tunnels

3. Safety aspects of railway and road tunnel: example of the Lötschberg railway tunnel and Mont-Blanc road tunnel

4. The fire in the Channel Tunnel

5. State of the road tunnel safety technology in Japan

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3