A multi-center retrospective comparative study of third generation Ceramic-on- Ceramic total hip arthroplasty in patients younger than 45 years with or without the sandwich liner: A ten-year minimum

Author:

He Bangjian1ORCID,Li Xigong2,Dong Rui1,Tong Peijian1,Sun Junying3

Affiliation:

1. Department of Orthopedics, The First Affiliated Hospital of Zhejiang Traditional Chinese Medicine University, Hangzhou, China

2. Department of Orthopedics, The First Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China

3. Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, China

Abstract

Background Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. However, the material in THA still remains one of the major concerns about the risk of fracture, due to its brittleness. Objective The present study aims at reporting the fracture rate of a series of ceramic-on-ceramic THAs with use of the sandwich liner combined with a ceramic femoral head, and attempt to detect the relative risk factors, possible cause and assesse the medium-term clinical results. Methods We retrospectively evaluated 282 patients (300 hips) with use of the sandwich liner ceramic-on-ceramic THA between 2001 and 2009 at three-centers. Patient assessment was based on demographic factors, including age, weight, gender and body-mass index. All patients were evaluated clinically and radio-graphically or computed tomography in consideration of dislocation, osteolysis, periprosthetic fracture, infection, loosening and implant fracture. Results five ceramic sandwich liners fracture (1.7%) were observed at an average of 7.3 years follow-up. These factors were irrelevant to the ceramic liner fracture, including age ( p = 0.205), weight ( p = 0.241), gender ( p = 0.553), body-mass index ( p = 0.736), inclination ( p = 0.727), and anteversion ( p = 0.606). The overall survival was 91.4% at 12 years with revision as the endpoint. Other complications included dislocation in two, perprosthetic fracture in two and osteolysis in eight hips. No hip had aseptic loosening of the implants was seen. Conclusions We found that the sandwich liner may be lead to a high rate of alumina fracture and osteolysis. We have discontinued the use of sandwich liner with THA since 2009.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3