Feasibility of Microwave Scissors-Based Off-Clamp Laparoscopic Partial Nephrectomy in a Porcine Model

Author:

Nguyen Ha Ngoc12ORCID,Yamada Atsushi1,Naka Shigeyuki13,Mukaisho Ken-Ichi4,Tani Tohru1

Affiliation:

1. Department of Research and Development for Innovative Medical Devices and Systems, Shiga University of Medical Science, Shiga, Japan

2. Department of Urology, Faculty of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam

3. Department of Surgery, Hino Memorial Hospital, Shiga, Japan

4. Division of Pathology, Shiga University of Medical Science, Shiga, Japan

Abstract

Objectives To assess the feasibility of off-clamp laparoscopic partial nephrectomy using microwave scissors. Methods We performed transperitoneal laparoscopic partial nephrectomy, without hilar clamping or renorrhaphy, using only microwave scissors for renal resection in a porcine model. For each kidney, 2 types of procedures were performed: a middle pole resection excising an area of 2-cm diameter and approximately 1-cm depth and a lower pole resection at the level of the lower polar line. The renal calyces exposed during renal resection were sealed and transected using microwave scissors. After 3 days of follow-up, the pigs were reoperated to inspect for postoperative complications. Euthanasia was performed to collect the remaining kidneys for histopathological examination. Results Ten procedures were successfully performed, without hilar clamping or suturing of the renal calyces and parenchyma, in 5 kidneys from 3 pigs. The median resecting time, blood loss, and lateral thermal injury were 23.2 min, 47.1 mL, and 6.8 mm in the middle pole resection, and were 15.1 min, 26.5 mL, and 6.9 mm in the lower pole resection, respectively. No complications were noted during reoperation, such as postoperative hemorrhage and major urine leakage. Extravasation occurred in 2 middle pole resections and 3 lower pole resections during retrograde pyelogram. Hematoxylin and eosin staining revealed thermal injury characterized by tissue microwave fixation in the near zone and acute coagulative necrosis in the intermediate zone. Conclusions Microwave scissors-based off-clamp laparoscopic partial nephrectomy is feasible in pigs and can be used for clinical applications.

Funder

JSPS KAKENHI

Nikkiso Co., Ltd.

Publisher

SAGE Publications

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3