Efficacy of a Laparoscopic Saline-Coupled Bipolar Sealer in Minimally Invasive Hepatobiliary Surgery

Author:

Sastry Amit1,Sulzer Jesse K.1,Passeri Michael1,Baker Erin H.1,Vrochides Dionisios1ORCID,McKillop Iain H.1ORCID,Iannitti David A.1,Martinie John B.1

Affiliation:

1. Carolinas Medical Center, Charlotte, NC, USA

Abstract

Hepatic resection presents unique surgical challenges to reduce blood loss during parenchymal division. The development of saline-coupled bipolar devices, in which hemostasis is achieved at lower temperatures than electrocautery or other bipolar sealing devices, have been employed for open hepatic resection. Saline-coupled bipolar devices have now become available for minimally invasive use. The goals of this study were to evaluate the feasibility and safety of a laparoscopic saline-coupled bipolar device for minimally invasive hepatectomy. Seventeen patients (median age 66 years, range 36-81) were consented for inclusion and enrolled. Patient demographics, intraoperative data, and surgeon feedback were collected. Seven robot-assisted partial hepatectomies, 9 laparoscopic partial hepatectomies, and 1 laparoscopic cholecystectomy with liver abscess resection were performed. Average operating time was 222 ± 33 minutes (median 188 minutes; range 61-564 minutes) with no difference between robotic versus laparoscopic time. Successful seals were achieved in all cases following application of 150 to 200 J energy (average 179 ± 3 J, average time to achieve a successful seal 9.3 ± 2.7 minutes). Estimated blood loss was 362 ± 74 mL (median 300 mL, range 5-1200 mL) and 3/17 patients received intraoperative blood transfusion. No bile leaks were detected in any of the patients. Median length of stay was 5 days (range 1-20 days), and there were no readmissions within 30 days. Postoperative morbidity occurred in 5/17 patients, all of which were Clavien Grade 1. There was no mortality within 90 days or complications requiring a return to the operating room, and there were no liver-specific morbidities. These data suggest the laparoscopic Aquamantys device represents a useful device for use in minimally invasive liver resection.

Funder

medtronic

Publisher

SAGE Publications

Subject

Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3