Abstract

Purpose. Mesh surgeries are counted among the most frequently applied surgical procedures. Despite global spread of mesh applying surgeries, there is no current systematic analysis of incidence and possible prevention of adverse events after mesh implantation. Materials and Methods. Based on the recommendations of IDEAL an in vitro test system for biocompatibility of surgical meshes has been generated (Innovation). Coating strategies for biocompatibility optimization have been developed (Development). The native and modified alloplastic materials have been tested in an animal model over 2 years (Exploration and Assessment and Long-term study). Results. In 3 meshes, implanted in sheep and explanted at 4 different time points (a, 3 months; b, 6 months; c, 12 months; and d, 24 months) over 24 months, thickness of inflammatory tissue (TVT a, 35 µm; b, 32 µm; c, 33 µm; d, 28 µm; UltraPro, a, 25 µm; b, 24 µm; c, 21 µm; d, 22 µm; PVDF a, 20 µm; b, 21 µm; c, 14 µm; d, 15µm), connective tissue (TVT a, 37 µm; b, 36 µm; c, 43 µm; d, 41 µm; UltraPro a, 33 µm; b, 32 µm; c, 40 µm; d, 38 µm; PVDF a, 25 µm; b, 22 µm; c, 22 µm; d, 24 µm), and macrophage infiltration (TVT a, 36%; b, 33%; c, 23%; d, 20%; UltraPro a, 34%; b, 28%; c, 25%; d, 22%; PVDF a, 24%; b, 18%; c, 18%; d, 16%) revealed comparable ranking characteristics at every time point after explantation. The in vivo performance of these meshes in a sheep model was predictable with a previously developed in vitro test system. Coating of meshes with autologous plasma prior to implantation seems to have a positive effect on the meshes biocompatibility. Conclusion. We have applied IDEAL criteria on a new innovation for surgical meshes. The results permit the generation of a ranking of currently available meshes with potential to optimize future meshes.

Publisher

SAGE Publications

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3