Bloodless Liver Resection Using Needle Arrays Under Alternating Electromagnetic Fields

Author:

Shan Yan-Shen1,Zuchini Roberto1,Tsai Hung-Wen1,Lin Pin-Wen1,Lee Gwo-Bin1,Lin Xi-Zhang2

Affiliation:

1. National Cheng Kung University, Tainan, Taiwan

2. National Cheng Kung University, Tainan, Taiwan,

Abstract

Background/Aim: Hemostasis is a major difficulty associated with hepatectomies. The authors designed a new thermal surgery system to reduce blood loss. Methods: The newly designed system consists of an alternating magnetic field generator and stainless steel needle arrays with thermosensitive bands. Lanyu pigs were used: 4 for the Kelly crushing method and 4 for the newly designed method. The procedures used were S4-S5 segmentectomies or left lateral segmentectomies, after which the amount of blood loss and operation times were compared. The pigs were observed for 4 weeks, after which liver pathologies were studied. Results: The blood loss in the method proposed by the authors was almost 0 mL, whereas with the Kelly crushing method it was 116 ± 35 mL. The method proposed in this study can save 15 to 25 minutes of operation time. The resected liver margins exhibited prominent apoptosis and fibrotic change in the remnant livers. Conclusions: The method proposed is a novel new way of performing thermal surgery.

Publisher

SAGE Publications

Subject

Surgery

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3