Prospective, Randomized, Comparative, Multicenter Study of the Hybrid Ultrasonic Advanced Bipolar Device and the Ultrasonic Coagulating Shears in Open Thyroidectomy

Author:

Kim Wan Wook1ORCID,Cho Jihyoung2,Jeon Young San3,Kim Insoo4,Jeong Young Ju5,Choi Jungeun6,Lee Moo Hyun2,Lee Jehyung3,Kang Jin Gu6,Tufano Ralph P.7,Kang Su Hwan6

Affiliation:

1. Department of Surgery, School of Medicine, Kyungpook National University, Daegu, Republic of Korea

2. Department of Surgery, School of Medicine, Keimyung University, Daegu, Republic of Korea

3. Department of Surgery, Goo Hospital, Daegu, Republic of Korea

4. Department of Surgery, Daegu Fatima Hospital, Daegu, Republic of Korea

5. Department of Surgery, School of Medicine, Catholic University of Daegu, Daegu, Republic of Korea

6. Department of Surgery, College of Medicine, Yeungnam University, Daegu, Republic of Korea

7. Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA

Abstract

Background. The hybrid ultrasonic advanced bipolar device (HUB) that integrates ultrasonic energy and advanced bipolar energy was recently developed and applied to thyroid surgery. The purpose of this study was to compare the efficacy and safety of HUB and ultrasonic coagulating shears for open thyroidectomy. Methods. A total of 200 patients were enrolled from April to September 2017 in this prospective, randomized, multicenter study. Patients were randomly assigned to an ultrasonic group (n = 101) or a hybrid group (n = 99). Results. Operation times were similar in the 2 study groups, that is, 54.2 ± 25.2 minutes in the ultrasonic group and 50.2 ± 21.6 minutes in the hybrid group. Postoperative surgical results and morbidities were no different in the 2 groups. However, the total amount of bleeding was significantly less in the hybrid group (13.0 ± 17.7 mg vs 8.6 ± 11.5 mg; P = .042). Conclusions. Our study showed that there was no significant difference between the 2 groups in postoperative surgical results and morbidity. The total bleeding amount was significantly less in the hybrid group. The study shows that HUB is comparable to the ultrasonic coagulating shears in terms of efficacy and safety during thyroid surgery.

Publisher

SAGE Publications

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3