Minced Cartilage Implantation in Acetabular Cartilage Defects: Case Series with 2-Year Results

Author:

Gebhardt Sebastian1,Hofer Andre1,Wassilew Georgi I.1,Sobau Christian2,Zimmerer Alexander13ORCID

Affiliation:

1. Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University of Greifswald, Greifswald, Germany

2. ARCUS Sportklinik, Pforzheim, Germany

3. Orthopädische Klinik Paulinenhilfe, Diakonie-Klinikum Stuttgart, Stuttgart, Germany

Abstract

Objective The objective was to evaluate clinical outcome and safety of arthroscopic, autologous minced cartilage implantation for acetabular cartilage lesions observed during hip arthroscopy to treat femoroacetabular impingement syndrome (FAIS). Design Eleven male patients, average age: 29.4 ± 5.4 years, average body mass index (BMI): 24.2 ± 2.2 kg/m2, scheduled for hip arthroscopy due to FAIS accompanied by an acetabular cartilage lesion were included in the case series. Cartilage tissue was harvested and minced from the loose cartilage flap at the chondrolabral lesion by arthroscopic shaver, augmented with autologous conditioned plasma, implanted into the defect, and fixated by autologous thrombin. Concomitant interventions were performed as indicated. The patients were evaluated preoperatively and at 24-month follow-up, using the International Hip Outcome Tool-12 (iHOT-12) and Visual Analog Scale (VAS) pain score and by magnetic resonance imaging (MRI) using the Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) grading scale at the 2-year follow-up. Results The defect size was on average 3.5 cm2 (1.5-4.5 cm2). From preoperatively to 2 years postoperatively, the iHOT-12 significantly improved from 50.2 ± 18 to 86.5 ± 19 ( P < 0.0001), and pain score decreased from 5.6 ± 1.8 to 1.0 ± 1.5 ( P < 0.0001) on the Visual Analog Scale pain score. Regarding functional outcome and pain, 10 of the 11 patients and all patients reached the minimal clinically important difference (MCID), respectively. The postoperative average MOCART score was 87.2 (± 9.2). No adverse events or reoperations were observed. Conclusions Arthroscopic, autologous minced cartilage implantation for treating full-thickness acetabular cartilage lesions in FAIS shows statistically and clinically significant improvement at short-term follow-up.

Funder

Clinician Scientist Program at University Medicine Greifswald.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Biomedical Engineering,Immunology and Allergy

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3