Ultrasound Tissue Characterization of Breast Biopsy Specimens

Author:

Edmonds P. D.1,Mortensen C. L.1,Hill J.R.1,Holland S.K.2,Jensen J. F.1,Schattner P.1,Valdes A. D.3,Lee R. H.4,Marzoni F. A.4

Affiliation:

1. Bioengineering Research SRI International Menlo Park, CA 94025

2. Toxicology SRI International Menlo Park, CA 94025

3. Electromagnetic Sciences Laboratories SRI International Menlo Park, CA 94025

4. Department of Surgery Palo Alto Medical Clinic & Foundation Palo Alto, CA 94301

Abstract

Results of measurements of ultrasound speed and absorption coefficients in the range 3 to 8 MHz in breast tissues at 37 C are reported and analyzed in attempts to identify a set of ultrasound parameters capable of discriminating normal, benign, and malignant tissues. We analyzed 118 tissue regions, comprising 47 normal, 55 benign, and 16 malignant by straight-line fitting of frequency dependence of attenuation. Data for ten additional regions, for a total of 128, became available and were added to the cohort when we subsequently fitted quadratic curves. Sound speed consistently emerged as the variable with greatest discriminating power, particularly for separating normal from benign and malignant tissue. Great difficulty was encountered in discriminating benign from malignant, even when the jackknife technique was used. More success was found with classification and regression trees (CART), although results were sensitive to assigned misclassification costs. Best results from straight-line fits were obtained when discriminating malignant from combined normal/benign data after randomly assigning 75 percent of the data to the learning set and 25 percent to the test set. Then, 23 out of 25 normal/benign and 4 out of 4 malignant cases in the test set were correctly classified. With quadratic fitting, best results were obtained in the three-class case — the false positive rate for malignancy was reduced to zero in the learning (0/31) and test (0/10) sets. Nevertheless, the false negative rate increased to 13 out of 31 (42 percent) in the learning set, while attaining zero (0/4) in the test set.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3