Artifact Reduction of Ultrasound Nakagami Imaging by Combining Multifocus Image Reconstruction and the Noise-Assisted Correlation Algorithm

Author:

Tsui Po-Hsiang1,Tsai Yu-Wei1

Affiliation:

1. Department of Medical Imaging and Radiological Sciences, Institute for Radiological Research, Chang Gung University, Taoyuan, Taiwan

Abstract

Several studies have investigated Nakagami imaging to complement the B-scan in tissue characterization. The noise-induced artifact and the parameter ambiguity effect can affect performance of Nakagami imaging in the detection of variations in scatterer concentration. This study combined multifocus image reconstruction and the noise-assisted correlation algorithm (NCA) into the algorithm of Nakagami imaging to suppress the artifacts. A single-element imaging system equipped with a 5 MHz transducer was used to perform the brightness/depth (B/D) scanning of agar phantoms with scatterer concentrations ranging from 2 to 32 scatterers/mm3. Experiments were also carried out on a mass with some strong point reflectors in a breast phantom using a commercial scanner with a 7.5 MHz linear array transducer operated at multifocus mode. The multifocus radiofrequency (RF) signals after the NCA process were used for Nakagami imaging. In the experiments on agar phantoms, an increasing scatterer concentration from 2 to 32 scatterers/mm3 led to backscattered statistics ranging from pre-Rayleigh to Rayleigh distributions, corresponding to the increase in the Nakagami parameter measured in the focal zone from 0.1 to 0.8. However, the artifacts in the far field resulted in the Nakagami parameters of various scatterer concentrations to be close to 1 (Rayleigh distribution), making Nakagami imaging difficult to characterize scatterers. In the same scatterer concentration range, multifocus Nakagami imaging with the NCA simultaneously suppressed two types of artifacts, making the Nakagami parameter increase from 0.1 to 0.8 in the focal zone and from 0.18 to 0.7 in the far field, respectively. In the breast phantom experiments, the backscattered statistics of the mass corresponded to a high degree of pre-Rayleigh distribution. The Nakagami parameter of the mass before and after artifact reduction was 0.7 and 0.37, respectively. The results demonstrated that the proposed method for artifact reduction allows a sensitive and effective scatterer characterization by Nakagami imaging.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference44 articles.

1. Acoustic properties of normal and cancerous human liver—I. Dependence on pathological condition

2. Acoustic properties of normal and cancerous human liver—II Dependence on tissue structure

3. Shung KK, Thieme GA. Ultrasonic Scattering in Biological Tissues. Boca Raton, FL: CRC Press; 1992

4. Holfman HC. Statistical Methods on Radio Wave Propagation. New York: Pergamon Press; 1960.

5. A general statistical model for ultrasonic backscattering from tissues

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3