A Novel Method for Prediction of Raised Intracranial Pressure Through Automated ONSD and ETD Ratio Measurement From Ocular Ultrasound

Author:

Singh Maninder1ORCID,Gupta Vishal2,Gupta Rajeev1,Kumar Basant1,Agrawal Deepak3

Affiliation:

1. Electronics and Communication Engineering Department, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, India

2. Ciena Corporation, Gurugram, India

3. JPNATC, All India Institute of Medical Sciences, New Delhi, India

Abstract

The paper presents a novel framework for the prediction of the raised Intracranial Pressure (ICP) from ocular ultrasound images of traumatic patients through automated measurement of Optic Nerve Sheath Diameter (ONSD) and Eyeball Transverse Diameter (ETD). The measurement of ONSD using an ocular ultrasound scan is non-invasive and correlates with the raised ICP. However, the existing studies suggested that the ONSD value alone is insufficient to indicate the ICP condition. Since the ONSD and ETD values may vary among patients belonging to different ethnicity/origins, there is a need for developing an independent global biomarker for predicting raised ICP condition. The proposed work develops an automated framework for the prediction of raised ICP by developing algorithms for the automated measurement of ONSD and ETD values. It is established that the ONSD and ETD ratio (OER) is a potential biomarker for ICP prediction independent of ethnicity and origin. The OER threshold value is determined by performing statistical analysis on the data of 57 trauma patients obtained from the AIIMS, New Delhi. The automated OER is computed and compared with the conventionally measured ICP by determining suitable correlation coefficients. It is found that there is a significant correlation of OER with ICP ( r = .81, p ≤ .01), whereas the correlation of ONSD alone with ICP is relatively less ( r = .69, p = .004). These correlation values indicate that OER is a better parameter for the prediction of ICP. Further, the threshold value of OER is found to be 0.21 for predicting raised ICP conditions in this study. Scatter plot and Heat map analysis of OER and corresponding ICP reveal that patients with OER ≥ 0.21, have ICP in the range of 17 to 35 mm Hg. In the data available for this research work, OER ranges from 0.17 to 0.35.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3