Integrated Endoscope for Real-Time 3D Ultrasound Imaging and Hyperthermia: Feasibility Study

Author:

Pua Eric C.1,Qiu Yupeng1,Smith S.W.1

Affiliation:

1. Department of Biomedical Engineering Duke University Durham, NC 27708

Abstract

The goal of this research is to determine the feasibility of using a single endoscopic probe for the combined purpose of real-time 3D (RT3D) ultrasound imaging of a target organ and the delivery of ultrasound therapy to facilitate the absorption of compounds for cancer treatment. Recent research in ultrasound therapy has shown that ultrasound-mediated drug delivery improves absorption of treatments for prostate, cervical and esophageal cancer. The ability to combine ultrasound hyperthermia and 3D imaging could improve visualization and targeting of cancerous tissues. In this study, numerical modeling and experimental measurements were developed to determine the feasibility of combined therapy and imaging with a 1cm diameter endoscopic RT3D probe with 504 transmitters and 252 receive channels. This device operates at 5 MHz and has a 6.3 mm × 6.3 mm aperture to produce real time 3D pyramidal scans of 60–120 degrees incorporating 64 × 64 = 4,096 image lines at 30 volumes/sec interleaved with a 3D steerable therapy beam. A finite-element mesh was constructed with over 128,000 elements in LS-DYNA to simulate the induced temperature rise from our transducer with a 3 cm deep focus in tissue. Quarter-symmetry of the transducer was used to reduce mesh size and computation time. Based on intensity values calculated in Field II using the transducer's array geometry, a minimum ISPTA of 3.6 W/cm2 is required from our endoscope probe in order to induce a temperature rise of 4°C within five minutes. Experimental measurements of the array's power output capabilities were conducted using a PVDF hydrophone placed 3 cm away from the face of the transducer in a watertank. Using a PDA14 Signatec data acquisition board to capture full volumes of transmitted ultrasound data, it was determined that the probe can presently maintain intensity values up to 2.4 W/cm2 over indefinite times for therapeutic applications combined with intermittent 3D scanning to maintain targeting. These values were acquired using 8 cycle bursts at a prf of 6 kHz. Ex vivo heating experiments of excised pork tissue yielded a maximum temperature rises of 2.3°C over 5 minutes of ultrasound exposure with an average rise of 1.8 ± 0.2°C over 5 trials. Modifications to the power supply and transducer array may enable us to reach the higher intensities required to facilitate drug delivery therapy.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3