Effects of Phase Aberration and Phase Aberration Correction on the Minimum Variance Beamformer

Author:

Chau Gustavo1,Dahl Jeremy2,Lavarello Roberto1

Affiliation:

1. Laboratorio de Imágenes Médicas, Departamento de Ingeniería, Pontificia Universidad Católica del Perú, Lima, Peru

2. Department of Radiology, Stanford University, Stanford, CA, USA

Abstract

The minimum variance (MV) beamformer has the potential to enhance the resolution and contrast of ultrasound images but is sensitive to steering vector errors. Robust MV beamformers have been proposed but mainly evaluated in the presence of gross sound speed mismatches, and the impact of phase aberration correction (PAC) methods in mitigating the effects of phase aberration in MV beamformed images has not been explored. In this study, an analysis of the effects of aberration on conventional MV and eigenspace MV (ESMV) beamformers is carried out. In addition, the impact of three PAC algorithms on the performance of MV beamforming is analyzed. The different beamformers were tested on simulated data and on experimental data corrupted with electronic and tissue-based aberration. It is shown that all gains in performance of the MV beamformer with respect to delay-and-sum (DAS) are lost at high aberration strengths. For instance, with an electronic aberration of 60 ns, the lateral resolution of DAS degrades by 17% while MV degrades by 73% with respect to the images with no aberration. Moreover, although ESMV shows robustness at low aberration levels, its degradation at higher aberrations is approximately the same as that of regular MV. It is also shown that basic PAC methods improve the aberrated MV beamformer. For example, in the case of electronic aberration, multi-lag reduces degradation in lateral resolution from 73% to 28% and contrast loss from 85% to 25%. These enhancements allow the combination of MV and PAC to outperform DAS and PAC and ESMV in moderate and strong aberrations. We conclude that the effect of aberration on the MV beamformer is stronger than previously reported in the literature and that PAC is needed to improve its clinical potential.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3