ARFI Ultrasound for In Vivo Hemostasis Assessment Postcardiac Catheterization, Part II: Pilot Clinical Results

Author:

Behler Russell H.1,Scola Mallory R.1,Nichols Timothy C.23,Caughey Melissa C.3,Fisher Melrose W.3,Zhu Hongtu4,Gallippi Caterina M.1

Affiliation:

1. Joint Department of Biomedical Engineering The University of North Carolina at Chapel Hill Chapel Hill, NC 27599

2. Division of Cardiology The University of North Carolina at Chapel Hill Chapel Hill, NC 27599

3. Department of Medicine The University of North Carolina at Chapel Hill Chapel Hill, NC 27599

4. Department of Biostatistics The University of North Carolina at Chapel Hill Chapel Hill, NC 27599

Abstract

In this second of a two part series, we present pilot clinical data demonstrating Acoustic Radiation Force Impulse (ARFI) ultrasound for monitoring the onset of subcutaneous hemostasis at femoral artery puncture sites (arteriotomies), in vivo. We conducted a randomized, reader-blinded investigation of 20 patient volunteers who underwent diagnostic percutaneous coronary catheterization. After sheath removal (6 French), patients were randomized to treatment with either standard of care manual compression alone or, to expedite hemostasis, manual compression augmented with a p-GlcNAc fiber-based hemostatic dressing (Marine Polymer Technologies, Danvers MA). Concurrent with manual compression, serial ARFI imaging began at the time of sheath removal and continued every minute for 15 min. Serial data sets were processed with custom software to (1) estimate the time of hemostasis onset, and (2) render hybrid ARFI/B-Mode images to highlight displacements considered to correspond to extravasted blood. Images were read by an observer blinded to the treatment groups. Average estimated times to hemostasis in patient volunteers treated with manual compression alone ( n = 10) and manual compression augmented by hemostatic dressing ( n = 9) were, respectively, 13.00 ± 1.56 and 9.44 ± 3.09 min, which are statistically significantly different ( p = 0.0065, Wilcoxon two-sample test). Example images are shown for three selected patient volunteers. These pilot data suggest that ARFI ultrasound is relevant to monitoring subcutaneous bleeding from femoral arteriotomies clinically and that time to hemostasis was significantly reduced by use of the hemostatic dressing.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology