We report a rare, but serious, complication of a malpositioned umbilical venous catheter in a term male infant who developed laceration, hematoma, and necrosis of liver, ascites, and left-sided obstructive uropathy secondary to extravasation of total parenteral nutrition. Abdominal paracentesis confirmed the presence of parenteral nutrition in the peritoneal cavity. Although, the umbilical venous catheterization is a common intravenous access used in neonatal intensive care units, judicious continued monitoring of its use should be practiced to avoid serious complications.