Facility Mammography Volume in Relation to Breast Cancer Screening Outcomes

Author:

Onega Tracy1,Goldman L. Elizabeth2,Walker Rod L.3,Miglioretti Diana L.34,Buist Diana SM3,Taplin Stephen5,Geller Berta M.6,Hill Deirdre A.7,Smith-Bindman Rebecca8

Affiliation:

1. Department of Biomedical Data Science, Department of Epidemiology, The Dartmouth Institute for Health Policy and Clinical Practice, Norris Cotton Cancer Center, Geisel School of Medicine at Dartmouth, Lebanon, NH

2. Department of Medicine, University of California, San Francisco, CA

3. Group Health Research Institute, Group Health Cooperative, Seattle, WA

4. Department of Public Health Sciences, University of California, Davis, CA

5. National Cancer Institute, Rockville, MD

6. Department of Radiology and Office of Health Promotion Research, University of Vermont, Burlington, VT

7. Department of Internal Medicine, University of New Mexico, Albuquerque, NM

8. Department of Radiology, University of California, San Francisco, CA

Abstract

Objectives To clarify the relationship between facility-level mammography interpretive volume and breast cancer screening outcomes. Methods We calculated annual mammography interpretive volumes from 2000–2009 for 116 facilities participating in the U.S. Breast Cancer Surveillance Consortium (BCSC). Radiology, pathology, cancer registry, and women’s self-report information were used to determine the indication for each exam, cancer characteristics, and patient characteristics. We examined the effect of annual total volume and percentage of mammograms that were screening on cancer detection rates using multinomial logistic regression adjusting for age, race/ethnicity, time since last mammogram, and BCSC registries. “Good prognosis” tumours were defined as screen-detected invasive cancers that were <15 mm, early stage, and lymph node negative at diagnosis. Results From 3,098,481 screening mammograms, 9,899 cancers were screen-detected within one year of the exam. Approximately 80% of facilities had annual total interpretive volumes of >2,000 mammograms, and 42% had >5,000. Higher total volume facilities were significantly more likely to diagnose invasive tumours with good prognoses (odds ratio [OR] 1.32; 95% confidence interval [CI] 1.10–1.60, for total volume of 5,000–10,000/year v. 1,000–2,000/year; p-for-trend <0.001). A concomitant decrease in tumours with poor prognosis was seen (OR 0.78; 95%CI 0.63–0.98 for total volume of 5,000–10,000/year v. 1,000–2,000/year). Conclusions Mammography facilities with higher total interpretive volumes detected more good prognosis invasive tumours and fewer poor prognosis invasive tumours, suggesting that women attending these facilities may be more likely to benefit from screening.

Publisher

SAGE Publications

Subject

Public Health, Environmental and Occupational Health,Health Policy

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3