Testing the Hip Abductor Muscle Strength of Older Persons Using a Handheld Dynamometer

Author:

Awwad Daniel H.1,Buckley Jonathan D.2,Thomson Rebecca L.2,O’Connor Matthew1,Carbone Tania A.3,Chehade Mellick J.13

Affiliation:

1. Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, South Australia, Australia

2. Nutritional Physiology Research Centre, University of South Australia, Adelaide, South Australia, Australia

3. Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia

Abstract

Objective: To investigate the reliability of a clinically applicable method of dynamometry to assess and monitor hip abductor muscle strength in older persons. Design: Bilateral isometric hip abductor muscle strength measured with a handheld dynamometer, patients supine with the contralateral hip positioned directly against a wall for stabilization. Reliability determined by comparing intra-assessor and inter-assessor results and comparison to a criterion standard (stabilized dynamometer with patients in the standing position). Setting: UniSA Nutritional Physiology Research Centre. Participants: Twenty-one patients older than 65 years were recruited from the Royal Adelaide Hospital. Main Outcome Measures: Intraclass correlation coefficients (ICCs), bias, and limits of agreement calculated to determine reliability. Results: Intra-assessor and inter-assessor ICCs were high (0.94 and 0.92-0.94, respectively). There was no intra-assessor bias and narrow limits of agreement (±2.4%). There was a small inter-assessor bias but narrow limits of agreement (0.6%-0.9% and ± 2.3%, respectively). There was a wide variation comparing results to the criterion standard (±5.0%-5.2% limits of agreement), highlighting problems attributed to difficulties that the test population had with the standing position used in the criterion standard test. Conclusions: Testing older persons’ hip abductor muscle strength while in the supine position with optimal pelvic stabilization using a handheld dynamometer is highly reliable. While further studies must be done to assess patients with specific pathologies, this test has potential application to monitor and evaluate the effects of surgical interventions and/or rehabilitation protocols for a variety of conditions affecting hip abductor function such as hip fractures and arthritis.

Publisher

SAGE Publications

Subject

Geriatrics and Gerontology,Rehabilitation,Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3