Do on-demand irrigation warmers provide an adequate intraoperative rate of irrigation for holmium enucleation of the prostate?

Author:

Chapman Richard Alexander1,Halliday Paul1

Affiliation:

1. Ninewells Hospital, UK

Abstract

Introduction: On-demand irrigation warmers are widely used to provide a convenient way of irrigating warmed fluids for endoscopic procedure. However, concern has been raised that flow rates via these devices are inadequate for safe operating. Holmium enucleation of prostate (HoLEP) requires significant volume and flow rate of irrigation. Poiseuille’s Law states the resistance of a tube will result in reduced flow and a reduction in pressure across the tube. The aim was to compare the irrigation rates provided by one such warming device compared to a standard giving set whilst simulating HoLEP and to monitor intravesical pressure. Methods: A simulated apparatus was set up to replicate HoLEP surgery. Simulated design rather than ‘real-life’ apparatus was used to allow for repeated testing in a more controlled environment and to avoid other variables due to operative differences. Comparison of irrigation rate and pressure difference was measured whilst using a standard irrigation set (Fresenius Kabi) with pre-warmed fluid and the Ranger irrigation warming system (3M). Pressure was measured using a pressure line passed via the working channel of the laser resectoscope. Results: The standard giving set demonstrated lower resistance and higher irrigation rates. The irrigation rate was 31% higher (7.2 vs 5.5 ml/s). A lower change in pressure across the standard giving set was found (20 vs 38 cm H2O). The resistance therefore is much higher in the Ranger irrigation system, which gave a much slower flow and greater drop in pressure. Conclusion: This unique demonstration has led to a quantitative assessment of commonly used giving sets and has shown irrigation rates via a standard giving set are 31% greater than through the Ranger irrigation warming system. On-demand fluid warmers are felt to result in poor intraoperative vision and pose a potential risk to patient safety during HoLEP and other urological procedures requiring high fluid volumes.

Publisher

SAGE Publications

Subject

Urology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3