The phenomenon of drug-coating embolism during lower extremity endovascular interventions with paclitaxel-coated balloon

Author:

Osipova Olesia S1ORCID,Gostev Alexander A1,Karpenko Andrey A1

Affiliation:

1. Center for Vascular and Hybrid Surgery, Meshalkin National Medical Research Center, Novosibirsk, Russian Federation

Abstract

Introduction There is a risk of distal embolization lower extremity endovascular interventions. Possibly a drug-coating embolism caused by coating detachment from intravascular devices. Methods This review focuses on providing updated information on distal embolism in endovascular revascularization of lower extremity arteries, including the use of drug-coated balloons. Results Drug-coating embolism is a special case of distal embolization during recanalization of the arteries of the lower extremities. Preclinical studies have demonstrated embolization of drug-coated balloons during angioplasty of lower extremity arteries. However, the clinical role of drug-coating embolism is not completely clear. A 2020 meta-analysis found an increased risk of major lower extremity amputation after drug-coated balloon angioplasty in patients with critical limb ischemia. But long-term research is emerging to support the safety of using these devices. Perhaps a more thorough assessment of the quality of life and the degree of compensation of lower limb ischemia with an intraoperative assessment of the frequency of peripheral embolizations using ultrasound emboli detection, as well as microcirculation with transcutaneous oximetry and laser Doppler flowmetry of the operated lower limb will allow a more detailed study of the phenomenon of drug-coating embolism and its impact on long-term clinical outcomes. Conclusion According to the results of preclinical studies, the use of paclitaxel-coated balloons leads to an increase in the concentration of paclitaxel in distal skeletal muscles. However, paclitaxel concentration in skeletal muscle was significantly higher in first-generation DCBs. The non-target effects of drug-coating balloon are not fully understood and require further study. Understanding the phenomenon of drug-coating embolism can help physicians to better assess the patient risk and to minimize complications.

Funder

Grant of the President of the Russian Federation

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3