Results of the Galician registry in the treatment of complex aortoiliac aneurysms with GORE® EXCLUDER® Iliac Branch Endoprosthesis (GALIBER)

Author:

Méndez Fernández Alba1ORCID,Fernández Noya Jorge1,Mosquera Arochena Nilo J2,Vidal Rey Jorge3,Calvin Álvarez Pablo4,Franco Meijide Francisco José5,Villardefrancos Gil Rosa2

Affiliation:

1. Department of Angiology and Vascular Surgery, Complexo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, Galicia, Spain

2. Department of Angiology and Vascular Surgery, Complexo Hospitalario Universitario de Ourense, Ourense, Galicia, Spain

3. Department of Angiology and Vascular Surgery, Hospital Álvaro Cunqueiro, Complexo Hospitalario Universitario de Vigo, Vigo, Galicia, Spain

4. Department of Angiology and Vascular Surgery, Hospital Povisa, Vigo, Galicia, Spain

5. Department of Angiology and Vascular Surgery, Complexo Hospitalario Universitario de A Coruña, A Coruña, Galicia, Spain

Abstract

Objective The objective of this study is to report the medium-term results of GORE® EXCLUDER® Iliac Branch Endoprosthesis (IBE, W. L. Gore & Associates, Flagstaff, Ariz) for the treatment of aortoiliac aneurysms by using the GALIBER registry. Methods Patients with aortoiliac or isolated common iliac/hypogastric aneurysms treated with Iliac Branch Endoprosthesis device between January 2014 and May 2019 were prospectively collected from 5 centers. Demographic, clinical, and radiologic data were extracted from electronic databases. Technical success was defined as successful implantation of the Iliac Branch Endoprosthesis device with exclusion of aortoiliac aneurysm, as well as patency of Iliac Branch Endoprosthesis in the follow-up. Iliac Branch Endoprosthesis patency was evaluated by Doppler ultrasound and/or computed tomography based on the protocol of each participant center. Follow-up was 731 days +/− 499. Results Between January 2014 and May 2019, 105 iliac arteries were treated with GORE® IBE device, in 81 patients (79 men, two women; mean age 71, range 52–91). Only seven patients (8.6%) were symptomatic. 60 patients (74%) had aortic and iliac enlargement. Thirty-three patients presented bilateral iliac aneurysms (40.7%): In twenty-four (29.6%) patients, an Iliac Branch Endoprosthesis device was implanted in both sides, and in nine patients (11.1%), one Iliac Branch Endoprosthesis was used with the embolization of the contralateral hypogastric artery. Technical success was achieved in the 99% (104/105 iliac branch device implanted). There were no procedural deaths or type I or III intraoperative endoleaks observed. During the follow-up (range 55–1789 days), 28 (34.5%) type II endoleaks were observed and one (1.2%) type Ia was observed. The patency of the hypogastric arteries treated with the iliac branch device was 98.1% during the follow-up (range 55–1789 days). In 30% of the patients with contralateral hypogastric embolization, some kind of complications was observed in the embolizated side: one developed ischemic colitis and two buttock claudication. Conclusions Preservation of internal iliac artery with the Iliac Branch Endoprosthesis device can be performed safely with excellent technical success and good medium-term patency rates. These results support hypogastric preservation whenever possible to prevent ischemic complications.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3