Prospective single-center study on the reliability of ipsilateral cerebral oximetry using near-infrared spectroscopy as a predictor for selective shunting during carotid endarterectomy

Author:

Alhaizaey Abdullah1ORCID,Yousif Mohamed2,Azazy Ahmed2,Saber Abdelgawad2,Safan Mohamed3,Elgamal Galal A3,Almalki Yahya4,Alhazmi Barrag5

Affiliation:

1. Division of Vascular Surgery, Aseer Central Hospital, King Khalid University, Abha, Kingdom of Saudi Arabia

2. Division of Vascular Surgery, Armed Forces Hospital, Southern Region, Kingdom of Saudi Arabia

3. Division of Anesthesia, Armed Forces Hospital, Southern Region, Kingdom of Saudi Arabia

4. Division of Vascular Surgery, Aseer Central Hospital, Abha, Kingdom of Saudi Arabia

5. Division of General Surgery, Armed Forces Hospital, Jazan, Kingdom of Saudi Arabia

Abstract

Objective Many techniques are available for the intraoperative assessment of brain perfusion during carotid endarterectomy, such as carotid stump pressure, near-infrared spectroscopy, somatosensory evoked potentials, transcranial Doppler, electroencephalography, and clinical assessment. The decision for selective carotid shunt insertion is dependent on clinical deterioration or the detection of cerebral hypoperfusion after cross-clamping of the internal carotid artery. Monitoring cerebral oximetry using near-infrared spectroscopy is a noninvasive technique for cerebral oxygen saturation measurement, reflecting changes in cerebral blood flow during carotid endarterectomy. The aim of this study was to evaluate the reliability of near-infrared spectroscopy as a predictor of selective shunting during carotid endarterectomy. Methods In total, 47 conventional carotid endarterectomy surgeries were performed at our hospital between March 2016 and December 2021. All surgeries were performed under a regional cervical block supplemented with local infiltration anesthesia. All patients were monitored by cerebral oximetry using bilateral near-infrared spectroscopy probes and clinical assessment through communication with the patient (numerical, visual, and verbal) to indicate a selective shunt. Near-infrared spectroscopy values were recorded before and after internal carotid cross-clamping and after declamping. Any decrease in ipsilateral cerebral oximetry-near-infrared spectroscopy values equal to or more than 20% from the pre-clamping baseline reading associated with deterioration in neurological status (hemiparesis, aphasia, or deterioration in level of consciousness) after internal carotid artery cross-clamping was considered an indication for intraluminal carotid shunting Results After internal carotid artery cross-clamping, 5 of 47 patients (10.6%) developed a significant drop in cerebral oxygen saturation associated with obvious clinical assessment deterioration in verbal communication and weakness in contralateral arm power. A Pruitt-Inahara carotid shunt was subsequently inserted, and 42 patients remained stable throughout surgery. The average decline in ipsilateral near-infrared spectroscopy values was 23.8% in patients with clinical deterioration. The average decline was 8.6% in patients who remained stable. Conclusions Monitoring ipsilateral cerebral oximetry using near-infrared spectroscopy is an easy and reliable method for indicating selective shunting during carotid endarterectomy. A 20% decrease in ipsilateral brain tissue oximetry after internal carotid artery cross-clamping provides a reliable cut-off value for selective intraluminal carotid shunting during carotid endarterectomy.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3