Treatment of iliac atherosclerotic lesions using the balloon-expandable dynamic bare metal stent: One-year outcomes of the BIODYNAMIC single-center retrospective analysis

Author:

Torsello Giovanni F12ORCID,Doerr Beatrix3,Donas Konstantinos2ORCID,Berekoven Bärbel2,Torsello Giovanni B2,Beropoulis Efthymios2ORCID

Affiliation:

1. Department Diagnostic and Interventional Radiology, Campus Virchow-Klinikum, Charité University Medicine, Berlin, Germany

2. Department of Vascular Surgery, St. Franziskus-Hospital, Münster, Germany

3. Coriuvar Consulting, Moosburg, Germany

Abstract

Objectives Endovascular therapy using balloon expandable stents has become the treatment standard for most iliac atherosclerotic lesions. We aimed to assess the safety and performance of the Dynamic stainless-steel balloon-expanding stent system in this location. Methods BIODYNAMIC is a retrospective single center study including consecutive patients with iliac lesions treated with the Dynamic stent system. Not included were implantations inside an endograft. The primary endpoint was freedom from major adverse limb events (MALE) at 12 months, defined as index limb amputation or target lesion revascularization (TLR). Secondary endpoints were procedure success, ankle brachial index (ABI) and Rutherford class change, mortality and freedom from TLR after 12 months. Results Within two years, 182 patients with 234 lesions in the common iliac artery were enrolled. Rutherford class 5 and 6 were present in 11.5% of patients, average stent diameter was 8.0 ± 0.5 mm and stented length 40.0 ± 15.3 mm. The primary endpoint was reached in 96.2% (225/234) of the cases, with six TLR (2.6%) and three target limb amputations (1.3%). Procedure success was obtained in all but three patients (98.4%). In paired analysis, ABI improved by 0.25 ± 0.21 from baseline to 0.90 ± 0.16 post-procedure and Rutherford class improved by −1.75 ± 1.53. There were four non-device–related deaths (2.2%). Freedom from TLR was 97%, 95.3%, 94% and 92.7% at 24, 36, 48 and 60 months, respectively. Conclusion The Dynamic balloon-expandable stent system proved to be safe and effective in a population with common iliac artery lesions.

Funder

Biotronik

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3