Clinical efficacy and safety of the PRO-glide device as a sUture-mediated ClosurE in Thoracic EndoVascular Aortic Repair in patients with previous groin intervention (from the PRODUCE-TEVAR Trial)

Author:

Çelik Ömer1,Şahin Ahmet Anıl1ORCID,Güner Ahmet1,Demir Ali Rıza1ORCID,Uzun Nedim2,Ertürk Mehmet1

Affiliation:

1. Department of Cardiology, Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey

2. Department of Emergency Medicine, Gaziosmanpasa Taksim Training and Research Hospital, Istanbul, Turkey

Abstract

Background While the percutaneous approach is increasingly preferred, suture-mediated closure devices have been put into clinical practice to close the femoral artery during procedures requiring a large-sized introducer. However, scar in the groin is considered a contraindication or an exclusion criterion for percutaneous procedures. The aim of our study was to investigate the outcomes and safety of Pro-Glide device as suture-mediated closure device in patients who underwent thoracic endovascular aortic repair with percutaneous femoral access ≥22 F who had previous groin intervention. Methods A total of 73 patients who underwent endovascular repair with percutaneous femoral access were retrospectively included in the study. Previous groin intervention was defined as history of open surgical access or large sheath insertion (>18 F) to femoral artery because of endovascular or valvular intervention. Patients were divided into two groups as who had previous groin intervention PGI (+) and had not PGI (−). Results A total of 73 patients [60 male (82.2%)] were included in the study. Seventeen patients had PGI, and 56 did not. When groups were compared in terms of sheath sizes, a significantly higher sheath sizes were used in PGI (+) patients (24.5 ± 1.1 F vs. 23.8 ± 0.9 F, p = 0.005). The overall success rate in the femoral approach with pre-close technique was statistically insignificant between two groups (94.1% vs. 96.4%, p = 0.55). One patient in PGI (+) group and two patients in PGI (−) had technical failure for percutaneous femoral approach. One patient (5.9%) in PGI (+) group and one patient (1.8%) in PGI (−) group had femoral complications after the procedures; however, there was no significant difference between the groups in terms of complications (5.9% vs. 1.8%, p = 0.13). Conclusion Pro-Glide device may be a safe and less invasive method for femoral access in patients with PGI and might not be considered as a contraindication for patients with history of PGI.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3