Affiliation:
1. Department of Radiology, Wujin Hospital Affiliated with Jiangsu University, Changzhou, China
2. Department of Radiology, The Wujin Clinical College of Xuzhou Medical University, Changzhou, China
Abstract
Objectives This paper is aimed to explore the value of double source CT angiography (DS-CTA) for diagnosing in-stent restenosis in lower limb artery. Methods From January 2016 to October 2018, all patients with stent in lower limb artery in our hospital were investigated by both DS-CTA and digital subtraction angiography. We measured the minimum lumen diameter and the diameter of the proximal normal vessels under each stent placement. The in-stent restenosis is defined as restenosis when the lumen area decreased by more than 50%. Digital subtraction angiography was performed within 1 week after DS-CT scan. Relationship between DS-CTA and digital subtraction angiography for diagnosing in-stent restenosis in lower limb artery was analyzed. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DS-CTA for diagnosis of in-stent restenosis were analyzed with digital subtraction angiography as the reference standard. A total of 68 stents were placed in 51 patients. Among these patients, 27 cases were diagnosed as in-stent restenosis, presenting as endovascular contrast agent bias or crescent filling defect with the lumen area reducing over 50%, 6 cases of which had no significant in-stent restenosis by digital subtraction angiography analysis. Furthermore, 12 cases were occlusion, in which there was no high density contrast agent in stents; the remaining 41 stents were unobstructed and the contrast agent was filled well, 8 cases of which had significant in-stent restenosis by digital subtraction angiography analysis. In addition, four stents were deformed or distorted. Statistical analysis demonstrated the concentrations of DS-CTA and digital subtraction angiography in diagnosing in-stent restenosis for lower limb artery were closely related, and the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DS-CTA were 72.4%, 84.6%, 77.8%, 80.5%, and 79.4%, respectively. Conclusion DS-CTA has a potential reliability for diagnosis of in-stent restenosis in lower limb artery, which may be further improved to be used for clinical interventional treatment of vascular diseases.
Subject
Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献