Exploring the value of the double source CT angiography in diagnosing in-stent restenosis in lower limb artery

Author:

Yun Jian12,Shen Ye12,He Yun12,Gong Bo12,Liu Minhai12,Wu Xiaosong12,Xu Jianxing12ORCID

Affiliation:

1. Department of Radiology, Wujin Hospital Affiliated with Jiangsu University, Changzhou, China

2. Department of Radiology, The Wujin Clinical College of Xuzhou Medical University, Changzhou, China

Abstract

Objectives This paper is aimed to explore the value of double source CT angiography (DS-CTA) for diagnosing in-stent restenosis in lower limb artery. Methods From January 2016 to October 2018, all patients with stent in lower limb artery in our hospital were investigated by both DS-CTA and digital subtraction angiography. We measured the minimum lumen diameter and the diameter of the proximal normal vessels under each stent placement. The in-stent restenosis is defined as restenosis when the lumen area decreased by more than 50%. Digital subtraction angiography was performed within 1 week after DS-CT scan. Relationship between DS-CTA and digital subtraction angiography for diagnosing in-stent restenosis in lower limb artery was analyzed. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DS-CTA for diagnosis of in-stent restenosis were analyzed with digital subtraction angiography as the reference standard. A total of 68 stents were placed in 51 patients. Among these patients, 27 cases were diagnosed as in-stent restenosis, presenting as endovascular contrast agent bias or crescent filling defect with the lumen area reducing over 50%, 6 cases of which had no significant in-stent restenosis by digital subtraction angiography analysis. Furthermore, 12 cases were occlusion, in which there was no high density contrast agent in stents; the remaining 41 stents were unobstructed and the contrast agent was filled well, 8 cases of which had significant in-stent restenosis by digital subtraction angiography analysis. In addition, four stents were deformed or distorted. Statistical analysis demonstrated the concentrations of DS-CTA and digital subtraction angiography in diagnosing in-stent restenosis for lower limb artery were closely related, and the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DS-CTA were 72.4%, 84.6%, 77.8%, 80.5%, and 79.4%, respectively. Conclusion DS-CTA has a potential reliability for diagnosis of in-stent restenosis in lower limb artery, which may be further improved to be used for clinical interventional treatment of vascular diseases.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3