Abstract

Objectives Endovascular repair (ER) of popliteal artery aneurysm (PAA) is an alternative to open repair. However, there is no standardized protocol for when to opt for ER and the decision is therefore at the discretion of the clinician. This study aims to evaluate the adherence to the Instruction For Use (IFU) in patients undergoing ER for PAA and factors associated with stent graft patency at one year. Methods The adherence to IFU provided by the manufacturer in 55 patients treated with Gore Viabahn® Endoprosthesis with Heparin Bioactive Surface for PAA between 2009 and 2019 were retrospectively analyzed. Duplex follow-up was performed at 30 days and one year. Results The two groups of patients treated within ( n = 10) and not within ( n = 45) IFU did not differ in patient demographics, diagnostic assessment, treatment or outcome. Forty-five patients (81.8%) received stent graft placement with at least one deviation according to IFU. Distal oversizing >20% was the most frequent deviation against IFU ( n = 22, 40.0%). Primary patency at one year was 72%. Diameter size difference >1 mm between overlapping stent grafts (6/14 [43%], p = 0.013) and renal insufficiency (5/12 [42%], p = 0.0086) were associated with lower primary patency at one year. Age-adjusted analysis of tortuosity index (HR 1.78/SD, 95% CI 1.17–2.71; p = 0.0071) and maximal PAA angle (HR 1.73/SD, 95% CI 1.018–2.95; p = 0.043) were associated with major amputation/mortality at end of follow-up. Conclusion The majority of patients undergoing ER for PAA were not treated within IFU. Diameter size difference >1 mm between overlapping stent grafts was associated with a higher loss of primary patency at one year. Multi-center studies with larger sample size and long-term follow up of patency are warranted.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3