Carotid stenting: Does stent design matter?

Author:

Shahat Mohamed1ORCID,Cieri Enrico2,Rocha-Neves Joao3ORCID,SA Khairy1

Affiliation:

1. Department of Vascular and Endovascular Surgery, Assiut University Hospital, Assiut University, Assiut, Egypt

2. Vascular and endovascular surgery unit university of Perugia, ospedale S.Maria della Misericordia, Perugia, Italy

3. Department of Biomedicine – Unit of Anatomy, Faculdade de Medicina da Universidade do Porto, Portugal

Abstract

Background Carotid artery stenting (CAS) is considered an important tool in carotid revascularization. Carotid artery stenting is usually performed by using self-expandable stent with different designs. The stent design influences many physical characteristics. Also, it may affect the complication rate with special relevance to perioperative stroke, hemodynamic instability, and late restenosis. Methods This study comprised all consecutive patients who underwent carotid artery stenting for atherosclerotic carotid stenosis from March 2014 to May 2021. Both symptomatic patient and asymptomatic patients were included. Patients with a symptomatic carotid stenosis of ≥50% or asymptomatic carotid stenosis of ≥60% were selected for carotid artery stenting . Patients with fibromuscular dysplasia and acute or unstable plaque were not included. Variables of clinical relevance were tested in multivariable analysis using binary logistic regression model. Results A total of 728 patients were enrolled. The majority of this cohort was asymptomatic (578/728, 79.4%), while 150/728 (20.6%) were symptomatic. The mean degree of carotid stenosis was 77.82 ± 4.73%, with a mean plaque length of 1.76 ± 0.55 cm. A total of 277 (38%) patients were treated with Xact® Carotid Stent System. Successful carotid artery stenting was achieved in 698 (96%) of patients. Of these patients, stroke rate in symptomatic patients was nine (5.8%), while in asymptomatic patients was 20 (3.4%). In a multivariable analysis, the open-cell carotid stent was not associated with a differential risk for combined acute and sub-acute neurologic complications as compared with closed-cell stents. Patients treated with open cell stents had a significantly lower rate of procedural hypotension ( P 0.0188) at bivariate analysis. Conclusion Carotid artery stenting is considered a safe alternative to CEA that can be used in selected average surgical risk patient. Different stent designs can affect the rate of major adverse events in carotid artery stenting patients, but further studies are necessary with avoiding different bias to study the effect of different stent designs.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3