Outcomes of endosutured aneurysm repair with the Heli-FX EndoAnchor implants

Author:

Karaolanis Georgios1ORCID,Antonopoulos Constantine N2ORCID,Koutsias Stylianos1,Antoniou George A34,Beropoulis Efthymios5ORCID,Torsello Giovanni5,Taneva Gergana T6ORCID,Donas Konstantinos P6

Affiliation:

1. Vascular Unit, Department of Surgery, University of Ioannina and School of Medicine, Ioannina, Greece

2. Cardiothoracic and Vascular Surgery Department, General Hospital of Athens “Evangelismos,” Athens, Greece

3. Department of Vascular and Endovascular Surgery, The Royal Oldham Hospital, Pennine Acute Hospitals NHS Trust, Manchester, UK

4. Division of Cardiovascular Sciences, School of Medical Sciences, University of Manchester, Manchester, UK

5. Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany

6. Department of Vascular Surgery, Research Vascular Centre, Asklepios Clinic Langen, University of Frankfurt, Germany

Abstract

Objective Endovascular aneurysm repair has gained field over open surgery for the treatment of abdominal aortic aneurysm. However, type Ia endoleak represents a common complication especially in hostile neck anatomy that is recently faced using endoanchors. We conducted a systematic review and meta-analysis to collect and analyse all the available comparative evidence on the outcomes of the endosuture aneurysm repair in patients with or without hostile neck in standard endovascular aneurysm repair. Methods The current meta-analysis was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. All the prospective and retrospective studies reporting primary use of the Heli-FX EndoAnchor implants were considered eligible for inclusion in this study. The main study outcomes (technical success of endoanchor implantation, incidence of type Ia endoleak, aortic stent graft migration and the percentage of patients who presented regression or expansion of aneurysm sac throughout the follow-up) were subsequently expressed as proportions and 95% confidence intervals. Results Eight studies with a total of 968 patients were included in a pooled analysis. The technical success of the primary endoanchor fixation was 97.12% (95%CI: 92.98–99.67). During a mean six months follow-up period, a pooled rate of 6.23% (95%CI: 0.83–15.25) of the patients developed a persistent type Ia endoleak despite the primary implantation. Migration of the main graft was reported in five studies, in which a 0.26% (95%CI = 0.00–1.54) of the patients required an additional proximal aortic cuff. Regression of the aneurysm sac was observed at 68.82% (95%CI: 51.02–84.21). An expansion of the aneurysm sac was found in 1.93% (95%CI: 0.91–3.24) of the participants. The overall survival rate was 93.43% (95%CI: 89.97–96.29) at a mean six months follow-up period. Conclusions Endosuture aneurysm repair with the Heli-FX EndoAnchor implants seems to be technically feasible and safe either for prevention or for repair of intraoperative type Ia endoleak. Despite the primary implants of endoanchors, few cases of persistent type Ia endoleak and migration are still conspicuous. Long-term follow up is needed to determinate the role of this therapeutic option in the treatment of aortic aneurysms.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3