Feasibility of a hip flexion feedback system for controlling exercise intensity and tibia axial peak accelerations during treadmill walking

Author:

Oliveira Nuno1ORCID,Chiu Chuang-Yuan2ORCID

Affiliation:

1. School of Kinesiology and Nutrition, University of Southern Mississippi, Hattiesburg, MS, USA

2. Sports Engineering Research Group, Sheffield Hallam University, Sheffield, UK

Abstract

The ability to meet high exercise intensities is limited by the increased risk of injury in some clinical populations. Previous studies have linked large tibia peak positive accelerations resulting from running to increased risk of developing lower-extremity injury. The purpose of this study is to determine the feasibility of using a hip flexion feedback system (HFFS) to meet and maintain different exercise intensities while maintaining low tibia axial accelerations. Ten healthy participants were tested on a HFFS test and an independent walking/running test to meet exercise intensities of 40% and 60% of heart rate reserve (HRR). During the HFFS test, the HFFS controlled in real time the exercise intensity by directing individuals to specific maximum hip flexion targets during walking and providing visual information that assists them in maintaining low tibia peak positive accelerations during the initial contact phase. Maximum hip flexion targets during walking are calculated based on real-time readings of the participant’s heart rate. During the independent test, exercise intensity was controlled independently by the participant using treadmill speed. Compared to the independent test, using the HFFS at 60% HRR resulted in similar heart-rate error but lower tibia peak positive accelerations. No differences were observed for the 40% HRR intensity. This paper describes a novel exercise approach that uses the individual’s heart rate to calculate maximal hip flexion targets that an individual should meet during treadmill walking. The HFFS also provides tibia peak positive peak acceleration cues. Therefore, the HFFS can increase and control exercise intensities while maintaining low tibia accelerations. In particular, the HFFS might be an alternative strategy to meet moderate to vigorous exercise intensities in populations at risk of developing lower-extremity injuries.

Publisher

SAGE Publications

Subject

General Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Increased hip flexion gait as an exercise modality for individuals with obesity;European Journal of Applied Physiology;2023-05-24

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3