Reliability and concurrent validity of a functional electromechanical dynamometer device for the assessment of movement velocity

Author:

Rodriguez-Perea Ángela1ORCID,Jerez-Mayorga Daniel2,García-Ramos Amador13,Martínez-García Dario1,Chirosa Ríos Luis J1ORCID

Affiliation:

1. Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Granada, Spain

2. Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago, Chile

3. Department of Sports Sciences and Physical Conditioning, Faculty of Education, Universidad Católica de la Santísima Concepción, Concepción, Chile

Abstract

The aims of the study were (i) to determine the reliability and concurrent validity of a functional electromechanical dynamometer (FEMD) to measure different isokinetic velocities, and (ii) to identify the real range of isokinetic velocity reached by FEMD for different prescribed velocities. Mean velocities were collected simultaneously with FEMD and a linear velocity transducer (LVT) in two sessions that were identical, consisting of 15 trials at five isokinetic velocities (0.40, 0.60, 0.80, 1.00, and 1.20 m·s−1) over a range of movement of 40 cm. The results obtained using each method were compared using Paired samples t-tests, Bland-Altman plots and the Pearson’s product–moment correlation coefficient, while the reliability was determined using the standard error of measurement and coefficient of variation (CV). The results indicate that the mean velocity values collected with FEMD and LVT were practically perfect correlations ( r > 0.99) with low random errors (<0.06 m·s−1), while mean velocity values were systematically higher for FEMD ( p < 0.05). FEMD provided a high or acceptable reliability for mean velocity (CV ≤ 0.24%), time to reach the isokinetic velocity (CV range = 1.68%–9.70%) and time spent at the isokinetic velocity (CV range = 0.53%–8.94%). These results suggest that FEMD offers valid and reliable measurements of mean velocity during a fixed linear movement, as well as a consistent duration of the isokinetic phase. FEMD could be an appropriate device to evaluate movement velocity during linear movements. More studies are needed to confirm the reliability and validity of FEMD to measure different velocity metrics during more complex functional exercises.

Funder

Ministerio de Ciencia, Innovación y Universidades

Publisher

SAGE Publications

Subject

General Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3