Level of agreement and reliability of ADR encoder to monitor mean propulsive velocity during the bench press exercise

Author:

Moreno-Villanueva Adrián1ORCID,Rico-González Markel23ORCID,Pérez-Caballero Carlos Esteban1,Rodríguez-Valero Guillermo1,Pino-Ortega José12ORCID

Affiliation:

1. Faculty of Sports Sciences, University of Murcia, San Javier, Spain

2. BIOVETMED & SPORTSCI Research Group, Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, San Javier, Murcia

3. Department of Physical Education and Sport, University of the Basque Country, UPV/EHU, Vitoria-Gasteiz, Spain

Abstract

This study aimed to evaluate the reliability and the level of agreement of the ADR encoder to measure the mean propulsive velocity (MPV) of the bar in the bench press (BP) exercise on the Smith machine. Eleven males (21.6 ± 1.5 years; body mass 76.05 ± 9.73 kg) performed the protocol with isometric phase prior to concentric muscle action (PP) and the protocol in the absence of isometric phase (N-PP) for BP exercise on Smith machine. ADR encoder reported reliability values with almost perfect correlations in all training zones and protocols (PP: ICC = 0.940–0.999, r = 0.899–0.997, CV = 1.56%–4.05%, SEM = 0.0022–0.0153,and MDC = 0.006–0.031 m/s; N-PP: ICC = 0.963–0.999, r = 0.946–0.998, CV = 0.70%–3.01%, SEM = 0.0012–0.0099, and MDC = 0.003–0.027 m/s). Although the levels of agreement were high in both protocols (PP: SEM = 0.0024–0.0204 m/s, MDC = 0.007–0.057 m/s; N-PP: SEM = 0.0034–0.0288 m/s, MDC = 0.009–0.080 m/s), ADR encoder considerably underestimated the MPV values in both protocols (PP: t = −2.239 to −9.486, p < 0.001–0.01; N-PP: t = −6.901 to −17.871, p < 0.001) with respect to the gold standard (T-Force). In conclusion, ADR encoder offers high reliability for the measurement of MPV in bench press exercise performed on Smith machine regardless of their execution mode, in the entire range of intensities. However, this device is not interchangeable with T-Force since it considerably underestimates the MPV values, especially at low loads (0%–40%). Furthermore, the use of too wide load ranges suggests that the data be interpreted with caution, pending further research to corroborate the findings presented.

Publisher

SAGE Publications

Subject

General Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3