The Use of Biphasic Calcium Phosphate Substitute (BCP) in Mandibular Defects in Dogs: Use of CBCT to Evaluate Bone Healing

Author:

Girard Nicolas1ORCID,Cauvin Edouard R. J.1,Gauthier Olivier2,Gatel Laure1

Affiliation:

1. Azurvet Veterinary Referal Center, Saint Laurent du Var, France

2. Department of Small Animal Surgery and Dentistry, Oniris College of Veterinary Medicine, Nantes, France

Abstract

This study aimed to assess the use of cone beam computed tomography (CBCT) to follow-up bone healing of mandibular bone defects in dogs, filled with a combination of autologous blood and millimetric BCP granules. CBCT was performed ≥4 weeks postoperatively. CBCT gray-scale values were measured from multiplanar reconstructions of the defects and compared to that of normal contralateral mandibular bone and to pure BCP/blood composite time 0 (T0) value. Other parameters, determined by affecting grades according to specific criteria included: bone ridge margin restoration; biomaterial homogeneity; bone-biomaterial interface. Results: 8 dogs with 14 defects were included. Median age was 7.2 years (1-15 years). Follow-up CBCT was performed 1 to 7.5 months postoperatively (mean 3.3 months). Defect CBCT gray-scale values at follow-up were significantly greater than T0 (p < 0.05). Ratios of maximum and minimum densities of the defects to contralateral mandibular bone followed a linear correlation with time (p < 0.05). The bone ridge margin was adequately restored in all the defects and significantly correlated with time (p = 0.03). Biomaterial homogeneity was fair to good in 11 defects and significantly correlated with the bone ridge margin parameter (p = 0.05) and time (p = 0.006). There was no significant correlation with the bone-material interface. The latter was satisfactory in 12 defects and significantly correlated with time (p = 0.01) but not with the other parameters. The biomaterial was more homogeneous in smaller defects and with increasing time. CBCT allowed effective assessment of bone healing via the measurement of CBCT gray-scale values and assessment of multiple radiological variables.

Publisher

SAGE Publications

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3