A comparative study of the 2D- and 3D-based skeleton avatar technology for assessing physical activity and functioning among healthy older adults

Author:

Lincke Alisa1ORCID,Fagerström Cecilia23,Ekstedt Mirjam45,Löwe Welf1,Backåberg Sofia2

Affiliation:

1. Faculty of Technology, Department of Computer Science and Media Technology, Linnaeus University, Växjö, Sweden

2. Faculty of Health and Life Sciences, Department of Health and Caring Sciences, Linnaeus University, Växjö, Sweden

3. The Research Section, Kalmar, Sweden

4. Faculty of Health and Life Sciences, Department of Health and Caring Sciences, Linnaeus University, Växjö, Sweden;

5. Department of Learning, Informatics, Management and Ethics, Karolinska Institutet, Stockholm, Sweden

Abstract

Background: Maintaining physical activity (PA) and functioning (mobility, balance) is essential for older adults’ well-being and quality of life. However, current methods (functional tests, self-reports) and available techniques (accelerometers, sensors, advanced movement analysis systems) for assessing physical activity and functioning have shown to be less reliable, time- and resource-consuming with limited routine usage in clinical practice. There is a need to simplify the assessment of physical activity and functioning among older adults both in health care and clinical studies. This work presents a study on using Skeleton Avatar Technology (SAT) for this assessment. SAT analyzes human movement videos using artificial intelligence (AI). The study compares handy SAT based on 2D camera technology (2D SAT) with previously studied 3D SAT for assessing physical activity and functioning in older adults. Objective: To explore whether 2D SAT yields accurate results in physical activity and functioning assessment in healthy older adults, statistically compared to the accuracy of 3D SAT. Method: The mobile pose estimation model provided by Tensorflow was used to extract 2D skeletons from the video recordings of functional test movements. Deep neural networks were used to predict the outcomes of functional tests (FT), expert-based movement quality assessment (EA), accelerometer-based assessments (AC), and self-assessments of PA (SA). To compare the accuracy with 3D SAT models, statistical analysis was used to test whether the difference in the predictions between 2D and 3D models is significant or not. Results: Overall, the accuracy of 2D SAT is lower than 3D SAT in predicting FTs and EA. 2D SAT was able to predict AC with 7% Mean Absolute Error (MAE), and self-assessed PA (SA) with 16% MAE. On average MAE was 4% higher for 2D than for 3D SAT. There was no significant difference found between the 2D and the 3D model for AC and for two FTs (30 seconds chair stand test, 30sCST and Timed up and go, TUG). A significant difference was found for the 2D- and 3D-model of another FT (4-stage balance test, 4SBT). Conclusion: Altogether, the results show that handy 2D SAT might be used for assessing physical activity in older adults without a significant loss of accuracy compared to time-consuming standard tests and to bulky 3D SAT-based assessments. However, the accuracy of 2D SAT in assessing physical functioning should be improved. Taken together, this study shows promising results to use 2D SAT for assessing physical activity in healthy older adults in future clinical studies and clinical practice.

Publisher

SAGE Publications

Subject

Health Informatics

Reference14 articles.

1. Evaluation of the Skeleton Avatar Technique for Assessment of Mobility and Balance Among Older Adults

2. Data-Driven Human Movement Assessment

3. Towards an Automated Assessment of Musculoskeletal Insufficiencies

4. THE PERFORMANCE OF SOME MACHINE LEARNING APPROACHES IN HUMAN MOVEMENT ASSESSMENT

5. Hagelbäck J, Lincke A, Löwe W, et al. On the agreement of commodity 3D cameras. In: Arabnia HR, Deligiannidis L, Tinetti FG, et al. (eds). Proceedings of the 2019 International Conference on Image Processing, Computer Vision, and Pattern Recognition. Long Beach, NV, 2019b, pp. 36–42.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3