Accuracy of Noninvasive Blood Pressure Monitoring in Critically Ill Adults

Author:

Haber Erin N.1ORCID,Sonti Rajiv1,Simkovich Suzanne M.1,Pike C. William2,Boxley Christian L.3,Fong Allan3,Weintraub William S.3,Cobb Nathan K.1

Affiliation:

1. Division of Pulmonary, Critical Care and Sleep Medicine, MedStar Georgetown University Hospital, Washington DC, USA

2. Georgetown University School of Medicine, Washington DC, USA

3. Division of Healthcare Delivery Research, MedStar Health Research Institute, Washington DC, USA

Abstract

Background Blood pressure (BP) is routinely invasively monitored by an arterial catheter in the intensive care unit (ICU). However, the available data comparing the accuracy of noninvasive methods to arterial catheters for measuring BP in the ICU are limited by small numbers and diverse methodologies. Purpose To determine agreement between invasive arterial blood pressure monitoring (IABP) and noninvasive blood pressure (NIBP) in critically ill patients. Methods This was a single center, observational study of critical ill adults in a tertiary care facility evaluating agreement (≤10% difference) between simultaneously measured IABP and NIBP. We measured clinical features at time of BP measurement inclusive of patient demographics, laboratory data, severity of illness, specific interventions (mechanical ventilation and dialysis), and vasopressor dose to identify particular clinical scenarios in which measurement agreement is more or less likely. Results Of the 1852 critically ill adults with simultaneous IABP and NIBP readings, there was a median difference of 6 mm Hg in mean arterial pressure (MAP), interquartile range (1-12), P < .01. A logistic regression analysis identified 5 independent predictors of measurement discrepancy: increasing doses of norepinephrine (adjusted odds ratio [aOR] 1.10 [95% confidence interval, CI 1.08-1.12] P = .03 for every change in 5 µg/min), lower MAP value (aOR 0.98 [0.98-0.99] P < .01 for every change in 1 mm Hg), higher body mass index (aOR 1.04 [1.01-1.09] P = .01 for an increase in 1), increased patient age (aOR 1.31 [1.30-1.37] P < .01 for every 10 years), and radial arterial line location (aOR 1.74 [1.16-2.47] P = .04). Conclusions There was broad agreement between IABP and NIBP in critically ill patients over a range of BPs and severity of illness. Several variables are associated with measurement discrepancy; however, their predictive capacity is modest. This may guide future study into which patients may specifically benefit from an arterial catheter.

Publisher

SAGE Publications

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3