Association of Body Weight Change and Fluid Balance With Extubation Failure in Intensive Care Unit Patients: A Single-Center Observational Study

Author:

Maezawa Shota12ORCID,Kudo Daisuke13ORCID,Miyagawa Noriko1,Yamanouchi Satoshi23,Kushimoto Shigeki13ORCID

Affiliation:

1. Department of Emergency and Critical Care, Tohoku University Hospital, Aoba-ku, Sendai, Japan

2. Department of Emergency and Critical Care, Osaki Citizen Hospital, Osaki, Japan

3. Division of Emergency and Critical Care Medicine, Graduate School of Medicine, Tohoku University, Aoba-ku, Sendai, Japan

Abstract

Purpose: To elucidate whether fluid balance and body weight change are associated with failed planned extubation. Materials and Methods: Patients who received invasive mechanical ventilation for over 24 hours were enrolled and divided into extubation success and extubation failure groups. Fluid balance and body weight fluctuation within 24 and 48 hours before extubation and from admission to planned extubation were calculated. The primary outcome was extubation failure (ie, all-cause reintubation within 72 hours). The association of extubation failure with fluid balance and body weight change was assessed via logistic regression analysis. Results: Extubation failure occurred in 12(7.4%)/161 patients. The extubation success group had a significantly lower fluid balance within 24 hours before extubation than did the extubation failure group (−276 mL [−1111 to 456] vs 1217 mL [503 to 1875], P = .002). However, fluid balance within 48 hours before extubation, cumulative fluid balance, and body weight change were not significantly different between the 2 groups. The sensitivity and specificity of water balance +1000 mL within 24 hours before extubation for the extubation failure group were 0.54 and 0.84, respectively, based on the receiver operating characteristic curve. Logistic regression analysis showed that fluid balance within 24 hours before extubation was associated with extubation failure (odds ratio: 22.9, 95% confidence interval: 4.1-128.4). Conclusions: A larger fluid balance within 24 hours before extubation is associated with extubation failure. Thus, fluid balance may be a good indicator of extubation outcome.

Publisher

SAGE Publications

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3