Unmasking the Hypovolemic Shock Continuum: The Compensatory Reserve

Author:

Suresh Mithun R.1,Chung Kevin K.23,Schiller Alicia M.4,Holley Aaron B.23,Howard Jeffrey T.1,Convertino Victor A.1

Affiliation:

1. Battlefield Health & Trauma Center for Human Integrative Physiology, US Army Institute of Surgical Research, JBSA Fort Sam Houston, TX, USA

2. Department of Medicine, Brooke Army Medical Center, JBSA Fort Sam Houston, TX, USA

3. Department of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD, USA

4. Department of Anesthesiology, University of Nebraska Medical Center, Omaha, NE, USA

Abstract

Hypovolemic shock exists as a spectrum, with its early stages characterized by subtle pathophysiologic tissue insults and its late stages defined by multi-system organ dysfunction. The importance of timely detection of shock is well known, as early interventions improve mortality, while delays render these same interventions ineffective. However, detection is limited by the monitors, parameters, and vital signs that are traditionally used in the intensive care unit (ICU). Many parameters change minimally during the early stages, and when they finally become abnormal, hypovolemic shock has already occurred. The compensatory reserve (CR) is a parameter that represents a new paradigm for assessing physiologic status, as it comprises the sum total of compensatory mechanisms that maintain adequate perfusion to vital organs during hypovolemia. When these mechanisms are overwhelmed, hemodynamic instability and circulatory collapse will follow. Previous studies involving CR measurements demonstrated their utility in detecting central blood volume loss before hemodynamic parameters and vital signs changed. Measurements of the CR have also been used in clinical studies involving patients with traumatic injuries or bleeding, and the results from these studies have been promising. Moreover, these measurements can be made at the bedside, and they provide a real-time assessment of hemodynamic stability. Given the need for rapid diagnostics when treating critically ill patients, CR measurements would complement parameters that are currently being used. Consequently, the purpose of this article is to introduce a conceptual framework where the CR represents a new approach to monitoring critically ill patients. Within this framework, we present evidence to support the notion that the use of the CR could potentially improve the outcomes of ICU patients by alerting intensivists to impending hypovolemic shock before its onset.

Funder

United States Army Medical Research and Materiel Command Combat Casualty Care Research Program

Publisher

SAGE Publications

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3