The Effect of Flow Trigger on Rapid Shallow Breathing Index Measured Through the Ventilator

Author:

Kheir Fayez1,Myers Leann2,Desai Neeraj R.3,Simeone Francesco1

Affiliation:

1. Section of Pulmonary Diseases, Critical Care and Environmental Medicine, Tulane University Health Sciences Center, New Orleans, LA, USA

2. Department of Biostatistics, Tulane University School of Public Health and Tropical Medicine, New Orleans, LA, USA

3. Chicago Chest Center, Elk Grove Village, IL, USA

Abstract

Background: The rapid shallow breathing index (RSBI) has the best predictive value to assess readiness for weaning from mechanical ventilation. At many institutions, this index is conveniently measured without disconnecting the patient from the ventilator, but this method may be inaccurate. Because modern ventilators have a base flow in the flow trigger mode that may provide a substantial help to the patient, we hypothesized that the RSBI is significantly decreased when measured through the ventilator with flow trigger even without continuous positive airway pressure (CPAP) and pressure support (PS). Methods: The RSBI was calculated using the values of minute ventilation and respiratory rate obtained either through the digital display of the ventilator or from a digital ventilometer. The RSBI was measured using 3 different methods: method 1, CPAP and PS both 0 cm H2O with flow trigger; method 2, CPAP and PS both 0 cm H2O without flow trigger; and method 3, using digital ventilometer. Results: A total of 165 measurements per method were obtained in 80 adult patients in the medical intensive care unit (MICU). The RSBI (breaths/min/L) values were 70.2 ± 26.5 with method 1, 85.4 ± 30.3 with method 2, and 80.1 ± 30.3 with method 3. The RSBI was significantly decreased using mechanical ventilation with flow trigger as compared with mechanical ventilation without flow trigger ( P < .0001) or digital ventilometer ( P < .0001). When method 1 was compared with methods 2 and 3, the RSBI decreased by 17% and 12%, respectively. Conclusions: The RSBI measurement is significantly decreased by the base flow delivered through modern ventilators in the flow trigger mode. If RSBI is measured through the ventilator in the flow trigger mode, the difference should be considered when using RSBI to assess readiness for weaning from mechanical ventilation.

Publisher

SAGE Publications

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3