Improvements in Accuracy and Confidence in Rhythm Identification After Cardiac Surgery Using the AtriAmp Signals

Author:

Brown Diane H.1ORCID,Zhang Xiao2,Al-Subu Awni M.1,Von Bergen Nicholas H.2ORCID

Affiliation:

1. Division of Pediatric Critical Care Medicine, Department of Pediatrics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA

2. Division of Pediatric Cardiology, Department of Pediatrics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA

Abstract

Objectives: Following cardiac surgery, 50% to 60% of patients with congenital heart disease will experience an arrhythmia. These arrhythmias are associated with increased morbidity and mortality. Therefore, rapid and accurate identification is paramount to the improvement of patient outcome. We hypothesize that the AtriAmp, a device which allows atrial electrogram (AEG) display on the bedside monitors, will increase provider accuracy and confidence in arrhythmia diagnosis. Design: A prospective observational study. Electrograms were collected from post-operative patients from the bedside monitors surface ECG and an AEG using the AtriAmp. A 12-question online survey was given to critical care and cardiology providers at 9 different programs across the country as well as being posted to the AAP SOCC fall newsletter. Six questions displayed signals from only the surface leads, while the other 6 showed the same arrhythmias with an AEG obtained from the AtriAmp. Answers were then evaluated for confidence and accuracy. A paired t-test along with mixed method modeling was used to assess the data. Setting: Cardiac pediatric ICU. Subjects: Providers in pediatric cardiology and pediatric critical care were evaluated on their ability to diagnose arrhythmias on surface ECG and AEG obtained from bedside monitor. Interventions: The accuracy and confidence of diagnosis of both surface and AEG signals were evaluated through an on-line survey. Results: Eighty-eight providers completed the survey. The study showed that interpreting with the AtriAmp signal, compared to the surface ECG only, significantly increased the accuracy ( P = .002) and confidence in provider rhythm diagnosis ( P < .001). Junctional ectopic tachycardia, sinus tachycardia, and complete heart block had the most significant increase in accuracy of diagnose when using the AtriAmp signal ( P < .001, P = .002, P = .010, respectively). Conclusion: Use of the AtriAmp increased provider accuracy and confidence in post-operative rhythm diagnosis when compared to diagnosis using the surface electrograms only.

Publisher

SAGE Publications

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3