Comparing Ventilation Parameters for COVID-19 Patients Using Both Long-Term ICU and Anesthetic Ventilators in Times of Shortage

Author:

Dijkman Wouter M.1,van Acht Niels M. C.23,van Akkeren Jesse P.1,Bhagwanbali Rhasna C. D.4,van Pul Carola23ORCID

Affiliation:

1. Department of Intensive Care, Máxima Medical Center (MMC), Veldhoven, the Netherlands

2. Department of Applied Physics, Eindhoven University of Technology, Eindhoven, the Netherlands

3. Department of Clinical Physics, Máxima Medical Center (MMC), Veldhoven, the Netherlands

4. Department of Anesthesiology, Máxima Medical Center (MMC), Veldhoven, the Netherlands

Abstract

In the first months of the COVID-19 pandemic in Europe, many patients were treated in hospitals using mechanical ventilation. However, due to a shortage of ICU ventilators, hospitals worldwide needed to deploy anesthesia machines for ICU ventilation (which is off-label use). A joint guidance was written to apply anesthesia machines for long-term ventilation. The goal of this research is to retrospectively evaluate the differences in measurable ventilation parameters between the ICU ventilator and the anesthesia machine as used for COVID-19 patients. In this study, we included 32 patients treated in March and April 2020, who had more than 3 days of mechanical ventilation, either in the regular ICU with ICU ventilators (Hamilton S1), or in the temporary emergency ICU with anesthetic ventilators (Aisys, GE). The data acquired during regular clinical treatment was collected from the Patient Data Management Systems. Available ventilation parameters (pressures and volumes: PEEP, Ppeak, Pinsp, Vtidal), monitored parameters EtCO2, SpO2, derived compliance C, and resistance R were processed and analyzed. A sub-analysis was performed to compare closed-loop ventilation (INTELLiVENT-ASV) to other ventilation modes. The results showed no major differences in the compared parameters, except for Pinsp. PEEP was reduced over time in the with Hamilton treated patients. This is most likely attributed to changing clinical protocol as more clinical experience and literature became available. A comparison of compliance between the 2 ventilators could not be made due to variances in the measurement of compliance. Closed loop ventilation could be used in 79% of the time, resulting in more stable EtCO2. From the analysis it can be concluded that the off-label usage of the anesthetic ventilator in our hospital did not result in differences in ventilation parameters compared to the ICU treatment in the first 4 days of ventilation.

Publisher

SAGE Publications

Subject

Critical Care and Intensive Care Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3