Affiliation:
1. Department of Housing and Interior Design, Yonsei University, Shinchon 134, Seoul 120-749, South Korea
Abstract
This research investigated resident behaviours in relation to kitchen ventilation in residential buildings in order to improve kitchen indoor air quality (IAQ) in South Korean living spaces. The research involved a survey study of 182 households, which identified resident behaviour with respect to ventilation, their satisfaction level regarding the IAQ, and their use and maintenance of range hoods in the kitchens. This paper describes the kitchen CO2 concentrations with both natural and mechanical ventilation. The adequacy of the ventilation behaviour was determined by monitoring the CO2 concentration and ventilation behaviours in 10 sampled households of residential buildings. The results showed that natural ventilation was conducted for less than 20 min once a day and that 23.3% of respondents used both natural ventilation and mechanical ventilators. Moreover, the results demonstrated that mechanical ventilators were not properly maintained. In addition, the average CO2 concentration was greater than 1000 ppm during cooking, and natural ventilation was more effective than were mechanical ventilators. Most residents performed inadequate kitchen ventilation to achieve comfortable IAQ. This study suggests ways to improve the ventilation behaviours of residents. The findings of this research should aid in the development of IAQ standards for Korean residential buildings and may contribute to the establishment of ventilation guidelines.
Subject
Public Health, Environmental and Occupational Health
Cited by
26 articles.
订阅此论文施引文献