Evaluation of Ventilation Effectiveness in the Kitchens of Beijing Flats

Author:

Nong Gang1,Shen Shaolin1,Chen Tian1

Affiliation:

1. Institute of Environmental Health and Engineering, Beijing, P.R. China

Abstract

The effects of different kinds of room ventilation were evaluated in an experi mental chamber and in kitchens of four residences in Beijing. Carbon monox ide was used as a tracer gas in the chamber, and this together with nitric oxide and nitrogen dioxide concentrations from the gas appliances were measured in the chamber and the kitchens. The ventilation styles evaluated were natural ventilation, an exhaust fan and a kitchen range hood. Their ventilation effec tiveness was related to design, air flow, the distance between an appliance and air vent, and position of the appliance in the kitchen. A kitchen range hood above the appliance associated with an extra fan installed in a high window was found to be the most effective way to control indoor air quality in the kitchens.

Publisher

SAGE Publications

Subject

Public Health, Environmental and Occupational Health

Reference15 articles.

1. Nong G., Niu S.: Study of factors influencing emission rates of pollutants from kitchen gas appliances; in Lunau F, Reynolds GL (eds): Indoor Air Quality and Ventilation. London, Selper, 1990, pp 353-358.

2. Review : Indoor Air Pollution from Combustion Sources in Developing Countries

3. Marbury MC, Harios DP, Sment JM, Spengler JD: Indoor residential NO2 concentrations in Albuquerque, New Mexico. JAPCA 1988;38: 392-398.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3