KT-1000 arthrometer: Conscious and unconscious test results using 15, 20, and 30 pounds of force

Author:

Highgenboten Carl L.1,Jackson Allen W.2,Jansson Ken A.3,Meske Neil B.1

Affiliation:

1. Orthopaedic Consultants, Dallas, Texas

2. University of North Texas, Denton, Texas

3. Orthopaedic and Reconstructive Surgery, Emporia, Kansas

Abstract

A recent published report indicated that the reliability and validity of anterior laxity measurements obtained by using the KT-1000 arthrometer were questionable. The purpose of our study was to examine the diagnos tic validity of anterior laxity measurements testing pa tients in conscious and unconscious states using the KT-1000 arthrometer at 15, 20, and 30 pounds of force. The sample included 68 patients with confirmed ante rior cruciate ligament disruption. They were given an terior-posterior drawer tests at 20° in both unconscious and conscious states; measurements were recorded at 15, 20, and 30 pounds of force. The results indicated that the measurements in the unconscious state were significantly higher (P < 0.01) than the values obtained in the conscious state. The anterior cruciate ligament- disrupted knees produced significantly higher (P < 0.01) anterior laxity. The difference between anterior cruciate ligament-disrupted knees and normal knees grew sig nificantly larger (P < 0.01) as force increased. More patients demonstrated a difference >2 mm between anterior cruciate ligament-disrupted knees and normal knees at 30 pounds (81 % to 83%) than at 20 pounds (64% to 72%) of force. Seventy-nine percent of the patients demonstrated a compliance index difference >1 mm using 15 and 30 pounds between the normal and anterior cruciate ligament-disrupted knee. These data provide statistical validity for the compliance index and support for the use of anterior laxity measurements at 30 pounds of force. However, approximately 20% of these patients did not demonstrate an anterior cruciate ligament-disrupted-normal knee difference >2 mm or a compliance index difference of >1 mm.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 68 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3