Modified Arthroscopic Latarjet Procedure: Suture-Button Fixation Achieves Excellent Remodeling at 3-Year Follow-up

Author:

Xu Jian1,Liu Haifeng1,Lu Wei1,Deng Zhenhan1,Zhu Weimin1,Peng Liangquan1,Ouyang Kan1,Li Hao1,Wang Daping1

Affiliation:

1. Department of Sports Medicine, Shenzhen Second People’s Hospital, First Affiliated Hospital of Shenzhen University, Shenzhen, China

Abstract

Background: Some studies have advocated the use of suture-button fixation during the Latarjet procedure to reduce complications associated with screw fixation. However, the sample size of these studies is relatively small, and their follow-up period is short. Purpose: To investigate the efficacy of the suture-button Latarjet procedure with at least 3 years of follow-up and remodeling of the coracoid graft. Study Design: Case series; Level of evidence, 4. Methods: A total of 152 patients who underwent the suture-button Latarjet procedure between February 2013 and February 2016 were selected, and 128 patients who met the inclusion criteria were enrolled in this study. Preoperative and postoperative clinical results were assessed. The position and healing condition of the coracoid graft and arthropathy of the glenoid and humeral head were also assessed using radiography and 3-dimensional computed tomography (CT). Results: The mean follow-up time was 40.3 ± 5.8 months. There were 102 patients included in this study. The mean visual analog scale score for pain during motion, the American Shoulder and Elbow Surgeons score, the Rowe score, and the Walch-Duplay score were improved considerably. A total of 100 grafts achieved bone union. The overall absorption rate was 12.6% ± 4.3%. Graft absorption mostly occurred on the edge and outside the “best-fit” circle of the glenoid. A vertical position was achieved in 98 grafts (96% of all cases) immediately postoperatively, with the mean graft midline center at the 4 o’clock position. In the axial view, CT showed that 89 grafts were flush to the glenoid, whereas 2 and 11 grafts were fixed medially and laterally, respectively. In all cases, the bone graft and glenoid tended to extend toward each other to form concentric circles during the remodeling process. During follow-up observations, the height of the 11 grafts that were positioned laterally (ie, above the glenoid level) exhibited a wave-curved change. No arthropathy was observed in any patient. Conclusion: Patient outcomes were satisfactory after the modified arthroscopic suture-button Latarjet technique. Graft absorption mostly occurred on the edge and outside the “best-fit” circle of the glenoid. The graft exhibited the phenomenon of ectatic growing when it fused with the glenoid and finally remodeled to a new concentric circle with the humeral head analogous to the original glenoid. Grafts positioned laterally did not cause arthropathy of the joints within the period of the study.

Funder

guangdong science and technology department

Health and Family Planning Commission of Shenzhen Municipality

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3