Radiographic Landmarks for Tunnel Positioning in Posterior Cruciate Ligament Reconstructions

Author:

Johannsen Adam M.1,Anderson Colin J.1,Wijdicks Coen A.1,Engebretsen Lars2,LaPrade Robert F.3

Affiliation:

1. Department of BioMedical Engineering, Steadman Philippon Research Institute, Vail, Colorado

2. Department of Orthopaedic Surgery, Oslo University Hospital, University of Oslo, Norway

3. The Steadman Clinic, Vail, Colorado

Abstract

Background: Consistent radiographic guidelines for tunnel placement in single- or double-bundle posterior cruciate ligament (PCL) reconstructions are not well defined. Quantitative guidelines reporting the location of the individual PCL bundle attachments would aid in intraoperative tunnel placement and postoperative assessment of a PCL reconstruction. Hypothesis: Consistent and reproducible measurements in relation to radiographic landmarks for the entire PCL and its individual bundle attachments are achievable. Study Design: Controlled laboratory study. Methods: The femoral and tibial PCL bundle attachment centers of 20 nonpaired fresh-frozen cadaveric knees were labeled using radio-opaque spheres and the attachment areas were labeled using barium sulfate. Anteroposterior (AP) and lateral radiographs of the femur and tibia were obtained, and measurements of the distances between the PCL bundle centers and landmarks were acquired. Results: On the AP femur view, the anterolateral bundle (ALB) and posteromedial bundle (PMB) centers were 34.1 ± 3.0 mm and 29.2 ± 3.0 mm lateral to the most medial border of the medial femoral condyle, respectively. The lateral femur images revealed that the ALB center was 17.4 ± 1.7 mm and the PMB center was 23.9 ± 2.7 mm posteroproximal to a line perpendicular to the Blumensaat line that intersected the anterior margin of the medial femoral condyle cortex. Anteroposterior tibia images revealed that the ALB and PMB centers were located 0.2 ± 2.1 mm proximal and 4.9 ± 2.9 mm distal to the proximal joint line, respectively. The PCL attachment center was 1.6 ± 2.5 mm distal to the proximal joint line. On the lateral tibia view, the ALB center was 8.4 ± 1.8 mm, the PCL attachment center was 5.5 ± 1.7 mm, and the PMB center was 2.5 ± 1.5 mm superior to the champagne glass drop-off of the posterior tibia. Conclusion: Radiographic measurements from several clinically relevant views of the femur and tibia were reproducible with regard to the anatomic locations of the ALB and PMB centers. The measurements from the lateral femur and tibia views provided the most clinically pertinent radiographic measurements intraoperatively. Clinical Relevance: This study established a set of clinically relevant radiographic guidelines for anatomic reconstruction of the PCL. The parameters set forth in this study can be used in both the intraoperative and postoperative settings for both single- and double-bundle PCL reconstructions.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3